– 23 –
Powerline Carrier Devices
UL:
Powerline Carrier devices and the 4300 Transformer are not UL Listed for fire or burglary functions and
are intended for home automation.
On-Board Triggers
UL:
If on-board triggers are used, the wiring between the control unit and the UL Listed device must be run in
conduit, be no more than 3 feet apart and have no intervening barriers or walls.
Phone Line/Phone Module Connections
UL:
The 4285 and 4286 modules are UL Listed only for use on residential fire and UL residential burglar
alarm installations.
Audio Alarm Verification Connections
UL:
UL installations using the AAV feature must use the ADEMCO UVCM module (part of the ADEMCO
UVS system).
Various System Trouble Displays
Alpha Display
Fixed Disp.
Meaning
CHECK
CHECK
A problem exists with the displayed zone(s) and requires attention.
SYSTEM LO BAT
BAT
If no zone number appears, indicates that the system's main standby
battery is weak.
LO BAT
BAT
If a zone number appears with aabout a twice-per-minute beeping at the
touchpad, indicates that a low-battery condition exists in the wireless
sensor displayed (zone “00” indicates a wireless touchpad). If the battery
is not replaced within 30 days, a “CHECK” display may occur.
Some wireless sensors use a non-replaceable long-life battery which
requires replacement of the entire unit at the end of battery life (e.g.,
5802, 5802CP).
no display
no display
Power Failure
If there is no touchpad display at all and the LEDs are unlit, operating
power (AC and battery) for the system has stopped and the system is
inoperative.
If the message “AC LOSS” (Custom English display) or “NO AC”
(English display) is displayed, the touchpad is operating on battery
power only.
If the battery standby capacity is used up during a prolonged AC power
outage, the control's power will shut down to minimize deep discharge of
the battery.
Comm. Failure
FC
A communication failure has occurred.
Busy-Standby
dl
If this remains displayed for more than 1 minute, the system is disabled.
NOTE for CANADIAN PANELS:
Power up time is 2 minutes, and CID
code 305 System Reset is sent if the [#] + [0] command is not performed
before the 2 minutes expires.