30
11.0 Detail Drawings
Figure 19 – INSERTA TEE Side Detail
Figure 18 – Under Drain Detail
INSERTA TEE DETAIL
NTS
INSERTA TEE
CONNECTION
CONVEYANCE PIPE
MATERIAL MAY VARY
(PVC, HDPE, ETC.)
PLACE ADS GEOSYNTHETICS 315 WOVEN
GEOTEXTILE (CENTERED ON INSERTA-TEE
INLET) OVER BEDDING STONE FOR SCOUR
PROTECTION AT SIDE INLET CONNECTIONS.
GEOTEXTILE MUST EXTEND 6" (150 mm)
PAST CHAMBER FOOT
INSERTA TEE TO BE
INSTALLED, CENTERED
OVER CORRUGATION
SIDE VIEW
SECTION A-A
A
A
DO NOT INSTALL
INSERTA-TEE AT
CHAMBER JOINTS
NOTE:
PART NUMBERS WILL VARY BASED ON INLET PIPE MATERIALS.
CONTACT STORMTECH FOR MORE INFORMATION.
CHAMBER
MAX DIAMETER OF
INSERTA TEE
HEIGHT FROM BASE OF
CHAMBER (X)
SC-310
6" (150 mm)
4" (100 mm)
SC-740
10" (250 mm)
4" (100 mm)
DC-780
10" (250 mm)
4" (100 mm)
INSERTA TEE FITTINGS AVAILABLE FOR SDR 26, SDR 35, SCH 40 IPS
GASKETED & SOLVENT WELD, N-12, HP STORM, C-900 OR DUCTILE IRON
(X)
NOTE:
SIDe I
NSERTA TEES CANNOT BE USED ON SC-160LP CHAMBERS.