Industrial PCs OPC6012/6015
21
© ads-tec GmbH • Heinrich-Hertz-Str. 1 • D-72622 Nürtingen
6
I
NTERFACES
6.1
I
NTERFACE SETUP
I
NTERFACE
IRQ
ADRESS
COM1
4
3F8h
COM2 (Touch)
3
2F8h
Pos : 26 /D atent ec hni k/Schnitts tell en/Spannungs versorgung/Spannungs versorg ung f ür VMT60xx- Seri e @ 2\ mod_1260450284020_6. doc @ 6853 @
6.2
24V
DC
POWER SUPPLY
The supply voltage is provided via a lead-through terminal including a screw connection
(Phoenix Contact COMBICON MC 1,5/4-STF3.81). (The figure shows the socket inside the
device)
PIN-NUMBER
SIGNAL NAME
1
PE
2
0V DC
3
NC
4
24V DC
Voltage tolerance
Input voltage: 24 V DC ± 20%.
Current consumption
The current consumption of this device depends on the equipment version
(e.g. if a heater or WLAN, etc. is installed.)
Switch-on current: 7A (1ms)
Standby current consumption: 0.25mA
Regular operation: 1.3A without heater
(without any additional load on the USB ports and without delivering the +5V
supply for the scanner)
Note:
The power supply can be protected with a slow-blow fuse of up to 4A.
Note:
The typical power consumption of this device is indicated in the "Technical details"
chapter.
Note:
If the case is connected with earth potential at the provided PE contact (e.g. by
connecting the PE contact with the device plug), the electrical insulation is no
longer given. This also applies if the device is installed by using a metal retainer
clip.
If you want to have the device electrically insulated from the power supply, you