Industrial PCs OPC6012/6015
8
© ads-tec GmbH • Heinrich-Hertz-Str. 1 • D-72622 Nürtingen
1.6
E
NVIRONMENTAL CONDITIONS
The device may be operated under the following conditions. Failure to observe these
specifications will terminate any warranty for this device. Ads-tec cannot be held liable for
any damages arising due to improper use and handling.
Temperature
in operation
-20 ... 55°C
for storage
-30 ... 60°C
Humidity:
In operation
10 … 85% without condensate
For storage
10 … 85% without condensate
Vibration resistance
Standard
EN 60068-2-
6 / 1 G, 10 … 150 Hz
Additionally applies
MIL-STD 810F (01.2000), annex C., figure 514.5C
(US highway truck transportation)
Shock resistance
Standard
EN 60068-2-27 / 5 G, with a half-wave of 11 ms duration
Pos : 8 /D at entechni k/ Allgemei ne Hinweis e/N ormen/N ormen f ür VMT- Seri e @ 2\ mod_1263309234182_6. doc @ 6984 @
1.7
S
TANDARDS
This device complies with the requirements and protective aims of the following EC
regulations:
This device meets the test requirements for granting the CE sign according to the
European test standards EN 61000-6-4 and EN 61000-6-2.
This device complies with the test requirements in accordance with DIN EN 60950
(VDE0805, IEC950) "Safety of Information Technology Equipment"
The device meets the DIN EN 60068-2-6 test requirements (sinus excitation).
The device meets the DIN EN 60068-2-27 test requirements (shock resistance
test).
Note:
All connected components, as well as cable connections must also meet these
requirements for compliance with the EMC legislation. For this reason, screened
bus and LAN cables including screened connectors must be used and installed
according to the instructions in this user manual.
Note:
By using the CE conformity declaration in this document, you can find detailed
information about the standards applicable to this device.