HDT8012
29
© ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen
10 Maintenance
10.1 Information on maintenance
ATTENTION
Maintenance must be performed only by qualified
electricians certified by ADS-TEC.
The following components of the system are maintenance parts. Use dry cleaning cloths to clean the
system.
Component
Type of maintenance
Maintenance interval
BIOS battery
Change ½ AA backup
battery. Type:
lithium battery 1/2AA 3V (e.g.
ADS-TEC part number: DZ-
SONS-04100-0)
3 years
Fuse
Replace 7A / 32Vdc
Littelfuse INC
Fuse F200 / F1200
type 453007.
Only necessary
if damaged
Exterior
Clean device with dry cloth.
As necessary, dependent on
installation site
Earth
connections
Secure connection and
correct operation
According to VDE0113
10.2 Information on storing the batteries
When storing batteries, always observe the relevant regulations: no direct sunlight, dry room, no frost,