3.6 Treatment and disposal of lithium batteries
This device contains a lithium battery for supplying the system clock with power as long as the supply
voltage is not connected. The battery has a life cycle of 3-5 years depending on which load is applied.
ATTENTION
Hazard due to thermal loads
The more the battery is exposed to higher
temperatures, the faster it ages.
Avoid thermal loads
WARNING
Hazard due to explosion
Danger of explosion if using incorrect battery
types.
Use the battery type recommended by the
manufacturer.
Lithium batteries should not be exposed to fire, soldered, recharged, opened, short-circuited, reversed
or heated above 100 °C and they should be disposed of properly as well as protected against sunlight,
moisture and condensation.
The battery type to be used is:
o
Lithium battery 1/2AA 3V FDK Corp. CR14250SE
o
ADS-TEC part number: DZ-SONS-04100-0
The used lithium battery should be disposed of in accordance with local legal regulations.