![ADLINK Technology HSLink HSL-AI16 User Manual Download Page 13](http://html1.mh-extra.com/html/adlink-technology/hslink-hsl-ai16/hslink-hsl-ai16_user-manual_2852692013.webp)
HSLink Introduction
•
5
Ø
Compare Figure 1.2, and Figure 1.4:
l
The MPC (Monitor PC) is replace by PC with HSLink Master.
l
The remote side PLC is replaced by HSLink slave I/O modules
l
The RS485 or RS232 cable is replaced by simple Ethernet cable.
Ø
HSLink as Remote Real-time DAQ
HSLink system gets many beneficial features as described on sections
before. Among those features, two are worthy of being particularly notified.
l
High Speed
l
Real time
To implement a DAQ application, the real-time characteristic is the most
important issue. With HSLink system, all I/O data are time-deterministic
refreshed. The sampling rate (or scan rate) is linearly dependent on the
number of slave I/O module used, ranges from 90µs (less than 3 modules)
to 2 ms (63 modules). These two features with HSLink’s born-nature
remoteness make HSLink very suitable for remote DAQ applications,
especially when real-time is concerned.
Figure 1.5: HSLink as real-time DAQ
16DI
16DI
16DI
HSL Master
RJ45/10BaseT
Slave I/O Module
Slave I/O Module
Slave I/O Module