ADLINK Technology DLAP-3000 Series User Manual Download Page 6

vi

Table of Contents

Leading

EDGE COMPUTING

A Appendix: Power Consumption .......................................75

A.1

Power Consumption Reference .........................................  75

B Appendix: Resource Mapping ..........................................77

B.1

BIOS Mapping in SPI ROM................................................  77

B.2

PCI/PCIe Devices ..............................................................  78

B.3

IRQ Lines (APIC Mode) .....................................................  79

B.4

IRQ Lines (PIC Mode)........................................................  80

B.5

System Memory Mapping ..................................................  81

B.6

System I/O Mapping ..........................................................  82

B.7

PCI/PCIe Interrupt Routing Mapping .................................  83

B.8

SMBus Slave Address Mapping ........................................  84

C Appendix: BIOS Setup.......................................................85

C.1

BIOS Setup Menu ..............................................................  85

C.2

Menu Structure ..................................................................  87

C.3

Main Menu .........................................................................  89

C.4

Advanced Menu .................................................................  92

C.5

Chipset.............................................................................  110

C.6

Security............................................................................  117

C.7

Boot .................................................................................  118

C.8

Save & Exit ......................................................................  119

D Appendix: DisplayPort BIOS Settings ...........................121

D.1

MXM P1000/P2000/T1000/RTX3000/RTX5000 ..............  121

D.2

MXM P3000/P5000..........................................................  122

E Appendix: Digital Input/Output Function Library .........123

Important Safety Instructions............................................. 125

Consignes de Sécurité Importante .................................... 127

Getting Service .................................................................... 131

Summary of Contents for DLAP-3000 Series

Page 1: ...TING DLAP 3000 3100 CF Series Embedded System supporting MXM Graphics Module with 8th 9th Generation Intel Core i7 i5 i3 in LGA1151 Socket User s Manual Manual Rev 1 1 Revision Date April 19 2021 Part...

Page 2: ...MPUTING Revision History Revision Release Date Description of Change s 1 0 2020 12 23 Initial release 1 1 2021 04 19 Add MXM cooler for RTX5000 and 500W power supply update specifications and DisplayP...

Page 3: ...ng out of the use or inability to use the product or documentation even if advised of the possibility of such damages Environmental Responsibility ADLINK is committed to fulfill its social responsi bi...

Page 4: ...eir respective companies Conventions Take note of the following conventions used throughout this manual to make sure that users perform certain tasks and instructions properly NOTE NOTE Additional inf...

Page 5: ...00 CF 5 2 2 DLAP 3100 CF 11 2 3 DLAP 3000 3100 CF Functional Block Diagrams 17 2 4 Display Options 19 2 5 Mechanical Dimensions 20 3 System Layout 25 3 1 Front Panel 25 3 2 Internal I O Connectors 33...

Page 6: ...B 7 PCI PCIe Interrupt Routing Mapping 83 B 8 SMBus Slave Address Mapping 84 C Appendix BIOS Setup 85 C 1 BIOS Setup Menu 85 C 2 Menu Structure 87 C 3 Main Menu 89 C 4 Advanced Menu 92 C 5 Chipset 11...

Page 7: ...ector Pin Definition 39 Table 3 11 COM Connector Pin Definition 40 Table 3 12 CPU System Fan Connector Pin Definition 41 Table 3 13 GPU Fan Connector Pin Definition 42 Table 3 14 Audio Connector Pin D...

Page 8: ...viii List of Tables Leading EDGE COMPUTING This page intentionally left blank...

Page 9: ...inition 29 Figure 3 7 Digital Input Circuit 30 Figure 3 8 Digital Output Circuit 30 Figure 3 9 COM Port Pin Definition 32 Figure 3 10 Mainboard Connectors Top 33 Figure 3 11 Mainboard Connectors Rear...

Page 10: ...x List of Figures Leading EDGE COMPUTING This page intentionally left blank...

Page 11: ...graphics processing ranging from Pascal to Turing GPUs 1 2 Features X ADLINK MXM Graphics module support Type A B up to 120W X 8th 9th Gen Intel Core i7 i5 i3 Celeron processors X Dual SODIMMs for up...

Page 12: ...g items are included in the package X 1x DLAP 3000 3100 CF Embedded Computer X Fasteners Z 3x M3 screws P head L4 Ni for M 2 P N 33 03013 0040 Z 8x M3 screws F head L4 Nylok for 2 5 storage bay P N 33...

Page 13: ...ler for P3000 P5000 P N 32 20823 0020 A0 X MXM cooler for T1000 P N 32 20830 0200 A0 X MXM cooler for RTX3000 P N 32 20823 1100 A0 X MXM cooler for RTX5000 P N 32 20839 1000 A0 X 12V 240W power adapto...

Page 14: ...4 Introduction Leading EDGE COMPUTING This page intentionally left blank...

Page 15: ...00E 3 1GHz 6M Cache 65W TDP LGA1151 DDR4 2400MHz support 4C 4T X Intel Core i3 9100TE 2 2GHz 6M Cache 35W TDP LGA1151 DDR4 2400MHz support 4C 4T X Intel Core i7 8700 3 2GHz 12M Cache 65W TDP LGA1151 D...

Page 16: ...B key supporting 2242 or 2280 for SATA storage module eSIM Optional DI O Default w o DIO Option 1x DI DO with 4 in 4 out Note Optional DIO Audio and TPM 2 0 must be chosen together TPM 2 0 Default no...

Page 17: ...midity 5 to 95 non condensing Vibration Operating 2Grms 5 500Hz 3 axes Package non operating 3 44Grms 10 1000Hz 3 axes w MXM w SSD Shock Operating and Package non operating 30G 11ms duration half sine...

Page 18: ...4T X Intel Core i3 9100TE 2 2GHz 6M Cache 35W TDP LGA1151 DDR4 2400MHz support 4C 4T X Intel Core i7 8700 3 2GHz 12M Cache 65W TDP LGA1151 DDR4 2666MHz support 6C 12T X Intel Core i7 8700T 2 4GHz 12M...

Page 19: ...Fi BT module 1x M 2 B key supporting 2242 or 2280 for SATA storage module eSIM Optional DI O Default w o DIO Option 1x DI DO with 4 in 4 out Note Optional DIO Audio and TPM 2 0 must be chosen together...

Page 20: ...to 95 non condensing Vibration Operating 2Grms 5 500Hz 3 axes Package non operating 3 44Grms 10 1000Hz 3 axes w MXM w SSD Shock Operating and Package non operating 30G 11ms duration half sine w MXM w...

Page 21: ...Hz 6M Cache 65W TDP LGA1151 DDR4 2400MHz support 4C 4T X Intel Core i3 9100TE 2 2GHz 6M Cache 35W TDP LGA1151 DDR4 2400MHz support 4C 4T X Intel Core i7 8700 3 2GHz 12M Cache 65W TDP LGA1151 DDR4 2666...

Page 22: ...dule 1x M 2 M key supporting 2242 or 2280 for SATA PCIe x4 storage module eSIM Optional DI O 1x DI DO with 4 in 4 out TPM 2 0 Yes Storage SATA 2x 2 5 SATA 6Gb s external drive bays 2x SATA 6Gb s signa...

Page 23: ...umidity 5 to 95 non condensing Vibration Operating 2Grms 5 500Hz 3 axes Package non operating 3 44Grms 10 1000Hz 3 axes w MXM w SSD Shock Operating and Package non operating 30G 11ms duration half sin...

Page 24: ...4T X Intel Core i3 9100TE 2 2GHz 6M Cache 35W TDP LGA1151 DDR4 2400MHz support 4C 4T X Intel Core i7 8700 3 2GHz 12M Cache 65W TDP LGA1151 DDR4 2666MHz support 6C 12T X Intel Core i7 8700T 2 4GHz 12M...

Page 25: ...for SATA storage module 1x M 2 M key supporting 2242 or 2280 for SATA PCIe x4 storage module eSIM Optional DI O 1x DI DO with 4 in 4 out TPM 2 0 Yes Storage SATA 2x 2 5 SATA 6Gb s external drive bays...

Page 26: ...to 95 non condensing Vibration Operating 2Grms 5 500Hz 3 axes Package non operating 3 44Grms 10 1000Hz 3 axes w MXM w SSD Shock Operating and Package non operating 30G 11ms duration half sine w MXM w...

Page 27: ...Audio Codec Default is without DIO Option DIO 4 bit in 4 bit out M 2_E_key CNx1 2230 size default SW PI3DBS12212A_Diodes BOM Option LAN3 i210_Intel Default is without TPM2 0 Option TPM 2 0 SLB9665_Inf...

Page 28: ...BOM Option SW PI3DBS12212A_Diodes M 2_B_key CNx1 2280 size default LAN2 i210_Intel DP CN LVDS CN DP CN SODIMM 2 DDR4 non ECC Socket SODIMM 1 DDR4 non ECC Socket LPC bus MXM3 1 slot p54 Port A Port B...

Page 29: ...first time to properly access the display settings in the BIOS menu Refer to Appendix D DisplayPort BIOS Settings for more information Table 2 1 Maximum Display Resolution Port Resolution Display Por...

Page 30: ...Leading EDGE COMPUTING 2 5 Mechanical Dimensions Figure 2 3 DLAP 3000 CF Front View including wall mount brackets and footpads Figure 2 4 DLAP 3100 CF Front View including footpads 78 96 75 75 83 235...

Page 31: ...Specifications 21 DLAP 3000 3100 CF Figure 2 5 DLAP 3000 3100 CF Left Side View Figure 2 6 DLAP 3000 3100 CF Right Side View units mm 182 75 units mm 83 182 75...

Page 32: ...22 Specifications Leading EDGE COMPUTING Figure 2 7 DLAP 3000 CF Rear View Figure 2 8 DLAP 3100 CF Rear View units mm 235 units mm This page intentionally left blank...

Page 33: ...ng temper ature limits if the airflow through the vents is restricted AVERTISSEMENT Pour viter d endommager le syst me assurez vous qu il y a un d gagement minimum de 10 cm autour des bouches d a ra t...

Page 34: ...24 Specifications Leading EDGE COMPUTING This page intentionally left blank...

Page 35: ...00 3100 CF 3 System Layout 3 1 Front Panel The DLAP 3000 3100 CF Series provides the following I O access features Figure 3 1 DLAP 3000 CF Front Panel I O Figure 3 2 DLAP 3000 CF Rear Panel I O A B C...

Page 36: ...26 System Layout Leading EDGE COMPUTING Figure 3 3 DLAP 3100 CF Front Panel I O Figure 3 4 DLAP 3100 CF Rear Panel I O A B C E F H K J I M L D G F G P N O...

Page 37: ...for COM1 RS 232 422 485 for COM2 K i210 AT LAN 5 LAN 6 DLAP 3100 CF only D DisplayPort x2 DP 1 DP 2 L 2x 2 5 hot swappable storage bay Bay 1 Bay 2 E i210 AT LAN 2 LAN 3 M Power on module See 3 1 1 Pow...

Page 38: ...on Lights blue when the system is powered on blinks when the system suspends to RAM and is off when the system suspends to disk M4 Remote Power On Button Connector MPN ALEX ALEX 9553 02 PBT BLACK Remo...

Page 39: ...5V 4 channel Digital Output X Output type Open drain N channel X MOSFET driver with internal pull high of 200 resistance X Source Sink current for all channels 22mA X VOH 4 956 to 5V X VOL 0 to 0 085V...

Page 40: ...30 System Layout Leading EDGE COMPUTING Figure 3 7 Digital Input Circuit Figure 3 8 Digital Output Circuit D G N N S 2 2 D G S 220 2 2K...

Page 41: ...ndicators Table 3 4 Speed LED Indicators LED Color Status Description Orange Off Ethernet port is disconnected On Ethernet port is connected with no activity Flashing Ethernet port is connected and ac...

Page 42: ...t support RS 232 422 485 modes by BIOS setting while COM1 supports only RS 232 Figure 3 9 COM Port Pin Definition Table 3 5 D Sub 9 pin Signal Function of COM Ports Pin Signal Name RS 232 RS 422 RS 48...

Page 43: ...inboard Connector Locations Figure 3 10 Mainboard Connectors Top WARNING Installation of add on devices must be carried out by ADLINK service personnel only Users must not disassemble the device thems...

Page 44: ...ocket for DIMM2 D CPU Fan connector E System Fan connector F 2x USB 2 0 Gen1 x1 pin header for U9 U14 G RS 232 pin header for COM1 H RS 232 422 485 pin header for COM2 I 2x USB 3 2 Gen1 x1 pin header...

Page 45: ...onnector U RTC battery connector V GPU fan connector W 12V DC in connector X DisplayPort C and D from MXM Y DisplayPort A and B from MXM Z LAN 1 and USB 3 2 Gen 1 x1 ports 1 and 2 AA LAN 4 and USB 3 2...

Page 46: ...r short time Power Up failures can indicate a corrupted BIOS or failure of the onboard power supply A blink code displays in cases of failure When the system is in an S3 state the Status LED flashes e...

Page 47: ...is provided on the mainboard for an inter nal USB dongle Figure 3 12 USB 2 0 Connector Pin Definition Table 3 7 USB 2 0 Connector Pin Definition Pin Signal Pin Signal 1 P5V_USB1 6 CN_U2_USB14_P 2 P5V...

Page 48: ...3 2 Connector Pin Definition Table 3 8 USB 3 2 Connector Pin Definition Pin Signal Pin Signal 1 NC 11 P5V_USB56 2 CN_U3_USB6_T_P 12 CN_U2_USB5_N 3 CN_U3_USB6_T_N 13 CN_U2_USB5_P 4 GND 14 GND 5 CN_U3_...

Page 49: ...Pin Definition Table 3 9 PCIe Power Connector Pin Definition 3 2 6 SATA Power Connector Figure 3 15 SATAConnector Pin Definition Table 3 10 SATA Connector Pin Definition Pin Signal 1 P_ 12V_S 2 P_ 12...

Page 50: ...onnector Figure 3 16 COM Connector Pin Definition Table 3 11 COM Connector Pin Definition Pin Signal Name RS 232 RS 422 RS 485 1 DCD Tx Tx Rx 2 DSR Tx Tx Rx 3 RxD Rx N A 4 RTS Rx N A 5 TxD N A N A 6 C...

Page 51: ...CPU System Fan Connectors Two connectors are provided for CPU and system fan power Figure 3 17 CPU System Fan Connector Pin Definition Table 3 12 CPU System Fan Connector Pin Definition Pin Signal 1 F...

Page 52: ...System Layout Leading EDGE COMPUTING 3 2 9 GPU Fan Connector Figure 3 18 GPU Fan Connector Pin Definition Table 3 13 GPU Fan Connector Pin Definition Pin Signal 1 FAN_OUT 2 FAN_IN 3 P_ 12V_FAN 4 FAN_G...

Page 53: ...2 10 Audio Connector Figure 3 19 Audio Connector Pin Definition Table 3 14 Audio Connector Pin Definition Pin Signal Pin Signal 1 AUDIO_Sense 6 GND_AUD 2 SPK_RP 7 A_MIC_IN_L 3 A_L_IN_L 8 SPK_LP 4 SPK_...

Page 54: ...RS 232 CCtalk Selection Jumper Table 3 15 COM1 RS 232 CCtalk Selection Jumper 3 2 11 2 Case Open Jumper Table 3 16 Case Open Jumper 3 2 11 3 ME Lock Jumper Table 3 17 ME Lock Jumper RS 232 CCtalk 1 3...

Page 55: ...lt BIOS WP 17 18 BIOS WP N A Undo default NOTE NOTE X S3 and S4 not supported under operating system X IAMT is not supported while pairing with Q370 X BIOS ME version information is shown as zero X Do...

Page 56: ...ule Connector Pin Definition Table 3 20 Power on Module Connector Pin Definition Pin Signal Pin Signal 1 P_ 5V0_A 9 LED_TEMP_ALARM 2 P_ 3V3_A 10 GND 3 PWR_BTN 11 LED_FAN_ALARM 4 LED_STANDBY 12 GND 5 R...

Page 57: ...Layout 47 DLAP 3000 3100 CF 3 2 13 DIO Connector Figure 3 22 DIO Connector Pin Definition Table 3 21 DIO Connector Pin Definition Pin Signal 1 5V_12V_S 2 GND 3 DI0 4 DI1 5 DI2 6 DI3 7 DO0 8 DO1 9 DO2...

Page 58: ...DCIN WARNING Before providing DC power ensure the voltage and polarity provided are compatible with the DC input Improper input volt age and or polarity can be responsible for system damage AVERTISSE...

Page 59: ...in Signal A1 Pin 1 on bottom GND A2 P_ 12V_S A3 P_ 12V_S A4 GND A5 JTAGE_CLK NC A6 JTAGE_DI NC A7 JTAGE_DO NC A8 JTAGE_MS NC A9 P_ 3V3_S A10 P_ 3V3_S A11 PCH_PLTRST L_BUF A12 GND A13 CLKOUT_PCIE_P7 A1...

Page 60: ...RX_P A30 GF_PCIEX24_RX_N A31 GND A32 NC A33 NC A34 GND A35 GF_PCIEX1_RX_P A36 GF_PCIEX1_RX_N A37 GND A38 GND A39 GF_PCIEX2_RX_P A40 GF_PCIEX2_RX_N A41 GND A42 GND A43 GF_PCIEX3_RX_P A44 GF_PCIEX3_RX_N...

Page 61: ...B15 GF_PCIEX5_21_TX_N B16 GND B17 PCH_CLK_REQ7 L B18 GND B19 GF_PCIEX22_TX_P B20 GF_PCIEX22_TX_N B21 GND B22 GND B23 GF_PCIEX23_TX_P B24 GF_PCIEX23_TX_N B25 GND B26 GND B27 GF_PCIEX24_TX_P B28 GF_PCI...

Page 62: ...DB40 Connector Pin Definition B39 GND B40 GND B41 GF_PCIEX3_TX_P B42 GF_PCIEX3_TX_N B43 GND B44 GND B45 GF_PCIEX4_TX_P B46 GF_PCIEX4_TX_N B47 GND B48 PCH_CLK_REQ7 L B49 GND Pin Signal 1 VCC_SPI_IN 2 G...

Page 63: ...C_FRAME 14 LPC_AD3 15 LPC_AD2 16 LPC_AD1 17 LPC_AD0 18 3 3V_SMC 19 3 3V_A 20 GND 21 TXD6 22 RXD6 23 FUMD0 24 RESET_IN 25 DATA 26 CLK 27 OCD0A 28 OCD0B 29 PWRBTN 30 SYS_RESET 31 CB_RESET 32 CB_PWROK 33...

Page 64: ...54 System Layout Leading EDGE COMPUTING This page intentionally left blank...

Page 65: ...t disassemble the device themselves Avertissement L installation d une carte d extension PCIe doit tre effectu e uniquement par le personnel de service ADLINK Les utilisateurs ne doivent pas d monter...

Page 66: ...56 Getting Started Leading EDGE COMPUTING 4 1 Installing 2 5 Storage Before installing a disk drive the drive bracket must be removed 1 Remove the thumbscrews and take out the 2 5 drive bay...

Page 67: ...D up to 9mm thick into the bracket and use the 4 provided M3 screws at 4kgf cm torque to attach the drive to the bracket 3 Gently slide the bracket back into the drive bay until the SATA connector on...

Page 68: ...COMPUTING 4 2 Installing an M 2 Module Remove the bottom panel before installing an M 2 Module 1 Remove 8 screws total to release the bottom panel from the chassis 4 on the bottom and 2 each on the le...

Page 69: ...Getting Started 59 DLAP 3000 3100 CF Left side screws Right side screws...

Page 70: ...60 Getting Started Leading EDGE COMPUTING 2 Remove the 4 screws attaching the left drive bay to the chassis...

Page 71: ...e the drive bay to reveal the M 2 socket underneath and install an M 2 module with an M3 screw at 4kgf cm torque P N 33 03013 0040 4 Reattach the drive bay and then screw the bottom panel back on to c...

Page 72: ...62 Getting Started Leading EDGE COMPUTING 4 3 Installing MXM P1000 P2000 T1000 Module 1 Remove the protective film from the MXM cooler...

Page 73: ...Getting Started 63 DLAP 3000 3100 CF 2 Attach the MXM cooler to the MXM module Tighten the screws in the order indicated at 4kgf cm torque...

Page 74: ...64 Getting Started Leading EDGE COMPUTING 3 Remove 2 screws to detach the top panel from the chas sis Remove the top panel to reveal the internal compo nents of the system...

Page 75: ...DLAP 3000 3100 CF 4 Attach the MXM module with 2 M3 screws P N 33 03306 0040 at 4kgf cm torque and plug the MXM cooling fan connector into the GPU fan connector 5 Screw the top panel back on to comple...

Page 76: ...66 Getting Started Leading EDGE COMPUTING 4 4 Installing MXM P3000 P5000 RTX3000 RTX5000 Module 1 Remove 2 screws to detach the top panel from the chassis...

Page 77: ...Getting Started 67 DLAP 3000 3100 CF 2 Remove the top panel to reveal the internal components of the system...

Page 78: ...68 Getting Started Leading EDGE COMPUTING 3 Remove the protective film from the MXM cooler bracket and attach the bracket to the bottom side of the MXM module...

Page 79: ...Getting Started 69 DLAP 3000 3100 CF 4 Attach the MXM module with 2 M3 screws P N 33 03306 0040 at 4kgf cm torque to the mainboard...

Page 80: ...arted Leading EDGE COMPUTING 5 Remove the protective film from the MXM cooler and lock the MXM cooler on the MXM module via the four spring screws Then plug the MXM cooling fan connector into the GPU...

Page 81: ...0086 0000 A0 and 4 rubber spacers PN 39 00039 0000 over the screw holes on the top of the fan 7 Use 4 screws PN 33 03320 0050 to secure the rubber spacers to the fan at 4kgf cm torque 8 Screw the top...

Page 82: ...4 5 Mounting 4 5 1 Install the Wall mount Brackets Use the 4 footpad screws to attach the 2 wall mount brackets to the chassis Utilisez les 4 incluses dans la bo te d accessoires pour fixer les 2 sup...

Page 83: ...ws torqued to 6kgf cm or the 6 mounting holes circled according to the spacing dimensions of the holes in the bracket as shown in Figure 2 9 DLAP 3000 3100 CF Top View Montez l appareil sur un mur l a...

Page 84: ...indows 10 drivers from the product page at https www adlinktech com Products Industrial_PCs_Fanless_ Embedded_PCs IPCSystems DLAP 3100 CF_Series The following drivers must be installed X Intel GPU X C...

Page 85: ...y Actual power consump tion will vary with different attached devices and operating system Table A 1 DLAP 3000 Power Consumption NOTE NOTE Information in this Appendix is for power budget planning and...

Page 86: ...35W CPU T1000 Full loading 185W 35W CPU P5000 Full loading 235W 35W CPU P3000 Full loading 210W 35W CPU P2000 Full loading 193W 35W CPU P1000 Full loading 182W NOTE NOTE X Sufficient power for the en...

Page 87: ...The size of the SPI ROM is 16MB for H310 and 32MB for Q370 chipsets From a software standpoint the serial peripheral interface SPI resides in the memory mapped space This function contains reg isters...

Page 88: ...4 2 Internal Shared SRAM 0 0x15 0 Internal I2C Controller 0 0 0x15 1 Internal I2 C Controller 1 0 0x16 0 Internal HECI 1 0 0x17 0 Internal SATA Controller AHCI 0 0x1C 0 Internal PCI Express Root Port...

Page 89: ...nterrupt from slave PIC N A No 3 Serial Port 2 COM2 IRQ3 via SERIRQ PIRQ No 4 Serial Port 1 COM1 IRQ4 via SERIRQ PIRQ No 5 N A IRQ5 via SERIRQ PIRQ No 6 N A IRQ6 via SERIRQ PIRQ No 7 N A IRQ7 via SERI...

Page 90: ...Port 2 COM2 IRQ3 via SERIRQ PIRQ See note 4 Serial Port 1 COM1 IRQ4 via SERIRQ PIRQ See note 5 N A IRQ5 via SERIRQ PIRQ See note 6 N A IRQ6 via SERIRQ PIRQ See note 7 N A IRQ7 via SERIRQ PIRQ See note...

Page 91: ...al Address Range Hex Size Description 4GB 2MB FFE00000 FFFFFFFF 2 MB High BIOS Area 4GB 18MB 4GB 17MB 1 FEE00000 FEEFFFFF 1 MB MSI Interrupt 4GB 20MB 4GB 19MB 1 FEC00000 FECFFFFF 1 MB APICConfiguratio...

Page 92: ...7 NMI mask 092h Reset Bit 0 Fast Gate A20 Bit 1 0A0h 0B1h 0B4h 0BDh Interrupt Controller 2 8259 equivalent 0B2h and 0B3h APM control and status port 0E0h 0EFh Available 0F0h Co processor error registe...

Page 93: ...0 INTA 16 INTA 16 INTA 16 INTA 16 INTA 16 INTA 16 Int1 INTB 17 INTB 17 INTB 17 Int2 INTC 18 INTC 18 INTC 18 Int3 INTD 19 INTD 19 INTD 19 INT Line PCIe Port 1 PCIe Port 5 PCIe Port 6 PCIe Port 11 PCIe...

Page 94: ...esource Mapping Leading EDGE COMPUTING B 8 SMBus Slave Address Mapping The following table lists the SMBus slave address 8 bit address ing mapping Device Address DIMM A 0A0h DIMM B 0A4h BMC 050h NXP 0...

Page 95: ...up Utility is invoked by pressing ESC or DEL when the system boots A system reboot is required when changes are made in the BIOS setup utility The BIOS Setup Utility includes the following hotkeys X F...

Page 96: ...er are based on a VT100 terminal connection via serial console with the following menu conventions X Using color The default BIOS setup fields are in black The BIOS setup fields currently not used are...

Page 97: ...f the table Main Advanced BIOS Information System Information Processor Information Memory Information PCH Information Board Information System Date System Time Access level CPU Configuration Graphics...

Page 98: ...ot Fast Boot Boot Order Save Changes and Exit Discard Changes and Exit Save Changes and Reset Discard Changes and Reset Save Changes Discard Changes Restore Defaults Save as User Defaults Restore User...

Page 99: ...OS Information Info only BIOS Vendor Info only BIOS Vendor BIOS Version Info only BIOS Version Build Date Info only BIOS build date MRC Version Info only MRC Version GOP Version Info only GOP Version...

Page 100: ...ription PCH SKU Info only PCH SKU Stepping Info only PCH Stepping Feature Options Description Board Information Info only Serial Number Info only Serial Number Manufacturing Date Info only Manufacturi...

Page 101: ...kday MM DD YYYY Requires the alpha numeric entry of the day of the week day of the month calendar month and all 4 digits of the year indicating the century and year Fri XX XX 20XX System Time HH MM SS...

Page 102: ...e Info only Displays the Processor L1 Data Cache size L1 Instruction Cache Info only Displays the Processor L1 Instruction Cache size L2 Cache Info only Displays the Processor L2 Cache size L3 Cache I...

Page 103: ...d C states Disabled Enabled Enables Disables CPU Power Management Allows CPU to go to C states when not 100 utilized C State Auto Demotion Disabled C1 C3 C1 and C3 Configure C State Auto Demotion C St...

Page 104: ...63 Feature Options Description Graphics Configuration Info only LVDS Info only eDP LVDS Disabled Enabled Enables Disables eDP LVDS LFP Panel Type VBIOS Default 640x480 800x600 1024x768 1280x1024 1400x...

Page 105: ...Backlight control function LVDS Backlight Brightness BMC Mode 0 255 Default 255 Set LVDS Backlight Brightness Percentage The change takes effect immediately GTT Mode 0 100 Default 100 Feature Options...

Page 106: ...Mode ATX OS will turn off system power when shutdown NOTE AT mode will not support S3 S4 so it will change Power Loss State to Power On PCI Express Wake Disabled Enabled Enables Disables PCI Express W...

Page 107: ...BIOS interface Feature Options Description SEMA Features Info only Uptime Power Cycles Counter Info only Uptime Power Cycles Counter System Restart Event Info only System Restart Event 1024 Bytes User...

Page 108: ...MC Board2 Temperature Info only Board2 Temperature SEMA Error Log Info only SEMA Error Log Soft Fan Info only Soft Fan Feature Options Description Flags Info only BMC Flags Info only BMC Flags BIOS Se...

Page 109: ...ly Min Board temperature Max Info only Max Board temperature GPU Temperatures Info only Current Info only Current GPU temperature Startup Info only Startup GPU temperature Min Info only Min GPU temper...

Page 110: ...100 Default 30 PWM Level Trigger Point 2 Info only Trigger Temperature 0 100 Default 65 Trigger Temperature PWM Level 0 100 Default 55 PWM Level Trigger Point 3 Info only Trigger Temperature 0 100 De...

Page 111: ...PWM Level Trigger Point 4 Info only Trigger Temperature 0 100 Default 85 Trigger Temperature PWM Level 0 100 Default 100 PWM Level GPU Smart FanTemperature Source GPU Sensor GPU Smart FanTemperature...

Page 112: ...Up Watchdog resets the system after a certain amount of time after power up Timeout 0 65535 Default 65535 The time the Power Up Watchdog should wait until it resets the system ATTENTION Pressing F12 d...

Page 113: ...sabled Enabled Disable Enable RI ping for Wake On Ring function PCH PME signal Feature Options Description Serial Console Redirection Info only COM1 Info only Console Redirection Disabled Enabled Enab...

Page 114: ...matched on both connected systems Long or noisy lines may require lower speeds Data Bits 7 8 Data Bits Parity None Even Odd Mark Space A parity bit can be sent with the data bits to detect some transm...

Page 115: ...Key Support for ANSI VT100 terminals Recorder Mode Disabled Enabled With this mode enabled only text will be sent This is to capture Terminal data Resolution 100x31 Disabled Enabled Enables Disables e...

Page 116: ...r to change State of Security Device Platform Hierarchy Disabled Enabled Enables Disables Platform Hierarchy Storage Hierarchy Disabled Enabled Enables Disables Storage Hierarchy Endorsement Hierarchy...

Page 117: ...23 hr For example enter 3 for 3am and 15 for 3pm Wake up minute 0 59 Default 0 Range 0 59 min Wake up second 0 59 Default 0 Range 0 59 sec Wake up minute increase 1 5 Default 1 Range 1 5 min Feature...

Page 118: ...time in seconds to press ESC key to abort PXE boot Use either or numeric keys to set the value Media detect count 1 50 Default 1 Number of times the presence of media will be checked Use either or nu...

Page 119: ...om file Feature Options Description Size Hex Number The valid RAM disk size should be multiples of the RAM disk block size Create Exit Yes Create a new RAM disk with the given starting and ending addr...

Page 120: ...d Disabled Enabled VT d capability Above 4GB MMIO BIOS assignment Disabled Enabled Enables Disables above 4GB MemoryMappedIO BIOS assignment Feature Options Description Memory Configuration Info only...

Page 121: ...hics Configuration Info only Graphics Turbo IMON Current 14 31 Default 31 Graphics turbo IMON current values supported 14 31 Primary Display Auto IGFX PEG Select which of IGFX PEG Graphics device shou...

Page 122: ...disabling Spread Spectrum Clocking for compliance testing Feature Options Description PCH IO Configuration Info only PCI Express Configuration Sub Menu PCI Express Configuration settings SATA Configu...

Page 123: ...PCI Express Configuration Info only PCI Express Clock Gating Disabled Enabled Enables Disables PCI Express Clock Gating for each root port Pcie Pll SSC Auto 0 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1...

Page 124: ...TA Port 3 Info only SATA device info Serial ATA Port 4 Info only SATA device info Feature Options Description USB Configuration Info only USB Overcurrent Disabled Enabled Select Disabled for pin based...

Page 125: ...SB Disabled Enabled U3_USB5_TX_P PIN HEADER USB Disabled Enabled U3_USB6_TX_P PIN HEADER USB Disabled Enabled U2_USB1_P EXTRENAL USB Disabled Enabled U2_USB2_P EXTRENAL USB Disabled Enabled U2_USB3_P...

Page 126: ...o Con figuration Feature Options Description Security Configuration Info only BIOS Lock Disabled Enabled Enables Disables the PCH BIOS Lock Enable feature Required to be enabled to ensure SMM protecti...

Page 127: ...up User Audit Deployed Secure Boot Info only Active Not Active Vendor Keys Info only Valid Modified Secure Boot Control Disabled Enabled Secure Boot feature is Active if Secure Boot is Enabled Platfor...

Page 128: ...es Disables boot with initialization of a minimal set of devices required to launch active boot option Has no effect for BBS boot options Boot Configuration Info only Boot Option 1 Hard Disk CD DVD US...

Page 129: ...tem setup without saving any changes Save Options Info only Save Changes Yes No Saves changes done so far to any of the setup options Discard Changes Yes No Discards changes done so far to any of the...

Page 130: ...120 BIOS Setup Leading EDGE COMPUTING This page intentionally left blank...

Page 131: ...led Enabled No Yes No Yes Auto Enabled Enabled No Yes No Yes IGFX Disabled Enabled No No No Yes PEG Disabled Enabled No Yes No Yes Auto Disabled Enabled No Yes No Yes IGFX Auto Enabled Yes No Yes Yes...

Page 132: ...to Disabled Enabled No Yes No Yes IGFX Auto Enabled Yes No Yes Yes PEG Auto Enabled No Yes No Yes Auto Auto Enabled No Yes No Yes IGFX Enabled Disabled Yes No Yes Yes PEG Enabled Disabled No Yes Yes Y...

Page 133: ...ustrial_PCs_Fanless_Embedded_PCs IPCSystems DLAP 3100 CF_Series To use the DI O function library for the DLAP 3100 series include the header file GpioLib h and linkage library GpioLib lib in the C pro...

Page 134: ...ortVal A new output state 0 or 1 Return values GPIO_OK on success GPIO_ERROR on failure RegisterInterruptEvent The event passed will be signaled when there is a change in state on a digital input pin...

Page 135: ...nce with Article 645 of the National Electrical Code and NFPA 75 X To avoid electrical shock and or damage to device Z Keep device away from water or liquid sources Z Keep device away from high heat o...

Page 136: ...onnect the power supply cord before loosening the thumbscrews and always fasten the thumbscrews with a screwdriver before starting the system up X It is recommended that the device be installed only i...

Page 137: ...s des salles de technologie de l information conformes l article 645 du National Electrical Code et la NFPA 75 X Pour viter les chocs lectriques et ou d endommager l appareil Z Tenez l appareil l cart...

Page 138: ...ppareil ne fonctionne pas ou ne fonctionne pas selon le manuel de l utilisateur X L appareil est tomb et ou a t endommag et ou pr sente des signes vidents de dommage X D branchez le cordon d alimentat...

Page 139: ...S curit Importante 129 DLAP 3000 3100 CF RISQUE DE BR LURES Partie chaude Ne touchez pas cette surface cela pourrait entra ner des blessures Pour viter tout danger laissez la surface refroidir avant d...

Page 140: ...130 Consignes de S curit Importante Leading EDGE COMPUTING This page intentionally left blank...

Page 141: ...l 1 408 360 0200 Toll Free 1 800 966 5200 USA only Fax 1 408 360 0222 Email info adlinktech com ADLINK Technology China Co Ltd 300 Fang Chun Rd Zhangjiang Hi Tech Park Pudong New Area Shanghai 201203...

Reviews: