Operation Theory
•
41
(UC _Counter=4, IC_Counter=3)
4 update coun ts, 3 iterations
DAWR
WFG_in_progress
Operation start
Trigger
Output Waveform
0
2
4
A single waveform
Figure 24: Finite iterative waveform generation with Post-trigger
and DLY2_Counter = 0 (Assuming the data in the
data buffer are 2V, 4V, 2V, 0V)
(UC _Counter=4, IC_Counter= 4)
4 update counts, infinite iterations
DAWR
WFG_in_progress
Operation start
Trigger
Output Waveform
waveform generation
won’t stop until software
stop function is
executed
0
2
4
Figure 25: Infinite iterative waveform generation with Post-trigger
and DLY2_Counter = 0 (Assuming the data in the
data buffer are 2V, 4V, 2V, 0V)
Note:
1.When running infinite iterative waveform generation, setting IC_Counter
is ineffective to the waveform generation. It only makes a difference
when setting stop mode III, please refer to section 4.2.2.3.
2.How to set finite and infinite iterative waveform generation is not in-
cluded in this manual. Please refer to software manual for further in-
formation.