Operation Theory
•
43
(UC _Counter=4, IC_Counter=3)
4 update counts, infinite iterations
DAWR
WFG_in_progress
Operation start
Trigger
Output Waveform
0
2
4
Software stop command
Figure 26: Stop mode I
(Assuming the data in the data buffer are 2V, 4V, 2V, 0V)
(UC _Counter=4, IC_Counter=3)
4 update counts, infinite iterations
DAWR
WFG_in_progress
Operation start
Trigger
Output Waveform
0
2
4
Software stop command
Figure 27: Stop mode II
(UC _Counter=4, IC_Counter=3)
4 update counts, infinite iterations
DAWR
WFG_in_progress
Operation start
Trigger
Output Waveform
0
2
4
Software stop command
Figure 28: Stop mode III