6
Specifications
2.11. Power Specifications
Power Modes
AT and ATX mode (AT mode startup controlled by SEMA Board Controller)
Standard Voltage Input
ATX: 12V±5% / 5Vsb ±5% or AT = 12V±5%
Wide Voltage Input
ATX: 4.75-20 V / 5Vsb ±5% or AT = 4.75-20 V
Power Management
ACPI 5.0 compliant, Smart Battery support
Power States
Supports C0, C1, C1E, C6L, C6, C7, S0, S3, S4, S5, S5 ECO mode (Wake-on-USB
S3/S4, WoL S3/S4/S5)
ECO Mode
Supports deep S5 for 5Vsb power saving
Please contact your ADLINK representative for the document “COM Express Module Power Consumption”.
2.12. Operating Temperatures
Standard Operating
Temperature
0°C to +60°C (Wide Voltage Input)
Storage: -20°C to +70°C
Extreme Rugged Operating
Temperature (optional)
-40°C to +85°C (Standard Voltage Input only, build option supported by Atom™ SKUs
only)
Storage: -40°C to +85°C
2.13. Environmental
Humidity
Operating: 5-90% RH, non-condensing
Storage:
5-95% RH (and operating with conformal coating)
Shock and Vibration
IEC 60068-2-64 and IEC-60068-2-27
MIL-STD-202F, Method 213B, Table 213-I, Condition A and Method 214A, Table 214-I,
Condition D
HALT
Thermal Stress, Vibration Stress, Thermal Shock and Combined Test
2.14. Specification Compliance
z
PICMG COM.0: Rev. 3.0 Type 6, Compact size 95 x 95 mm
2.15. Operating Systems
Standard Support
•
Windows 10 Enterprise 64-bit
•
Linux 64-bit
•
VxWorks 64-bit (under verification)
Extended Support (BSP)
•
Linux (64-bit)
•
VxWorks 64-bit (under verification)
Summary of Contents for cExpress-AL
Page 8: ...2 Introduction This page intentionally left blank ...
Page 36: ...30 Pinouts and Signal Descriptions This page intentionally left blank ...
Page 44: ...38 Module Interfaces This page intentionally left blank ...
Page 48: ...42 Smart Embedded Management Agent SEMA This page intentionally left blank ...
Page 88: ...82 BIOS Setup This page intentionally left blank ...
Page 98: ...92 BIOS Checkpoints Beep Codes This page intentionally left blank ...