![Adey FL1-03-06631 Installation And Servicing Download Page 15](http://html1.mh-extra.com/html/adey/fl1-03-06631/fl1-03-06631_installation-and-servicing_3047375015.webp)
15
PARAMETER PROGRAMMING MODE - DATA LOGGING MENU
(Code: 111)
#
Parameter
Description
Default
Range
DL1
Last Service Date
Automatically updates when a new service date
has been entered and will be visible next time the
user accesses parameters
-
-
DL2
Service Date
Automatically updates when a new service date
has been entered
-
-
DL3
Pump Hours
Total pump operation time (Auto-Update)
0 - 999
1 = 24 hrs
DL4
Current water
flow I/min
Flow rate through sensor at that point in time
Auto-
Update
DL5
Water Volume in
last 24 hours
Amount of water that has passed through the filter
during the previous 24 hours
Auto-
Update
DL6
Water volume
since last
Pressure
Difference Alarm
activation
Flow rate through sensor at that point in time
Auto-
Update
DL7
Total Water
Volume
Total amount of water that has passed through the
filter since the unit was last powered ON
Auto-
Update