27
8. VISCA protocol command list
When the camera is operated normally, it can be controlled via RS232C/RS485 port
(VISCA IN). Parameters of RS232C serial port are as follows:
Baud rate: 2,400/4,800/9,600/115,200 bit/s; start bit: 1 bit; digit bit: 8 bits; stop bit: 1 bit;
verification bit: none
After powering on, camera rotates to left bottom first, and then returns to middle. Zoom
lens zooms out to the furthest and zooms in to the nearest, and finishes self-inspection.
If the camera has a saved #0 preset, after initialization, camera will go to #0 preset.
Afterwards, user can use a serial port command to control the camera.
Return commands
Ack/Completion Message
Command package
Notes
ACK
z0 41 FF
Returned when the command is accepted.
Comp
letion z0 51 FF
Returned when the command has been executed.
z = camera 8
Error Messages
Command
package
Notes
Syntax Error
z0 60 02 FF
Returned when the command format is different or
when a command with illegal command parameters is
accepted
Command Not
Executable
z0 61 41 FF
Returned when a command cannot be executed due to
current conditions. For example, when commands
controlling the focus manually are received during
auto focus.
Control command
Command
Function
Command package
Notes
AddressSet
Broadcast
88 30 01 FF
Address setting
IF_Clear
Broadcast
88 01 00 01 FF
I/F Clear
CommandCancel
8x 21 FF
CAM_Power
On
8x 01 04 00 02 FF
Power ON/OFF
Off
8x 01 04 00 03 FF
CAM_Zoom
Stop
8x 01 04 07 00 FF
Tele (Standard)
8x 01 04 07 02 FF
Wide (Standard)
8x 01 04 07 03 FF
Tele (Variable)
8x 01 04 07 2p FF
p = 0(low) - 7(high)
Wide (Variable)
8x 01 04 07 3p FF
Summary of Contents for RADA A-TC01