36 —
Custom Word Substitutes for VIP Module Annunciation
A substitute word can be programmed for each of the 60 custom words used in your alpha zone descriptions. The VIP
Module will announce this substitute word in place of the custom word that is displayed on the alpha keypad. For example,
an alarm display of "John's Bedroom" could be announced as "Son's Bedroom," since there is no annunciation for the custom
word "John." Note that if a substitute word is not assigned, the VIP Module will not annunciate the zone descriptor at all, but
will only annunciate the zone number.
To enter custom word substitutes, do the following:
1. From Data Field Programming Mode, press #93 to display the "ZONE PROG?" prompt.
2. Press 0 (NO) to each menu option until the "CUSTOM INDEX ?" prompt is displayed.
CUSTOM INDEX ?
1=YES 0=NO
0
Enter 1 at this prompt.
CUSTOM WORD NO.
00=QUIT
Enter the custom word number (01-60) for which a voice substitute is desired. Enter 00 to quit
this Programming Mode.
Press [
✱
] to accept entry.
01 ENTER INDEX #
Enter the 3-digit substitute word index number from the Relay Voice Descriptors and Custom
Word Substitutes Vocabulary list found in the
Relay Voice Descriptors part of this section.
Press [
✱
] to accept entry.
The "CUSTOM WORD NO." prompt will be displayed. Enter the next custom word number to
be substituted or enter 00 to quit.
System Layout Worksheets
As with any security system, you should first define the installation. This includes determining how many partitions will be
used, how many zones per partition, and how many users per partition. You will also need to determine what peripheral
devices will be needed, and basic system options such as exit/entry delays, etc. The control panel itself should be located in
an area that will facilitate wire runs to all partitions, and will allow access to power and telephone circuits.
To help you lay out a partitioned system, use the following worksheet. This will further simplify the programming
process.
PARTITIONS
Partition #
Descriptor
(4 char max)
Prim.
Sub. #
Sec.
Sub. #
Alpha Default Message
(32 character maximum)
Partition 1
Partition 2
Keyswitch Arming Partition Assignment (1-2 or 9):
Wireless Keypad Partition Assignment (1-2):
Voice Module Partition Assignment (1-2):
Use Partition Descriptor (yes/no)?
Common Lobby Partition Assignment (1-2):
COMMUNICATION OPTIONS BY PARTITION
Option
Part. 1
Part. 2
Swinger Suppression Count
00-15; 00=no suppression
Cancel Report After Disarm
Dialer Reports for Panic (* + 1)
Dialer Reports for Panic (# + 3)
Dialer Reports for Panic (* + #)
Dialer Reports for Duress
Burglary Alarm Communications Delay
(16 sec.)
www.PDF-Zoo.com