10.2.2  Connection Diagram Size4 CBI280 

 

  RJCONN45:  It  is  a  normal  RJ45  cable 

also provided by ADELSystem. It is possible connect in daisy chain up to 32 devices, max distance 
1000m, from the Output AUX2 and Aux3. 

  RJUSB280: is cable interface RS485 – USB, max lenght 2m, for the connection to PC 

Note:  If  both,  DPY351  and  ADELViewsystem,  are  running  in  the  same  network  at  the  same  time,  The 
DPY351 must by set in the Modbus as “Viewmode”.  

10.2.3 Connection Diagram Size3 CBI500 

 

 

 
 

 

 

  DPYCONN500:  is  a  special  cable  for  the  connection  of  CBI  Size3  and  the  other  device;  max  leght 

0.5m 

  RJ45COUPLER: is e T connection RJ45 for daisy Chain with CBI Size3 

  RJCONN45: It is a normal IT cable also provided by ADELSystem. It is possible connect in daisy chain 

up to 3 devices, max distance 100m, from the Output AUX2. 

  RJUSB500: is cable interface RS485 – USB, max leght 2m, for the connection to PC 

 

10.2.4 Bus Termination (Size 3) 

Inside the device are present the following electric diagram for the polarization of the Modbus line: 
Fail-safe: 
 

  560 Ohm (Pull Up) at 5 V 

  560 Ohm (Pull Down) at 0 V 

Terminations: 

  120 Ohm (LT) between lines 

 

Summary of Contents for ALL IN ONE CBI Series

Page 1: ...y efficiency reduces risk of battery damage and allows a safe operation in permanent connection Predefined curves can be selected by jumpers or DIP switch to optimize the charge of different battery t...

Page 2: ...or Load DC Bus one Input Output for connection to the battery N 1 battery 12 Vdc for CBI 12xx N 2 battery 12 Vdc connected in Series for CBI 24xx N 4 battery 12 Vdc connected in Series for CBI 48xx 5...

Page 3: ...installation clearance of 10 mm left right between two power supplies and avoid installing the power supplies on top of each other Note Avoid return voltage e g from a decelerating motor or battery w...

Page 4: ...45 min 20 h Load 12 A No 3 min 12 min 30 min 600 min Load 15 A No No 9 min 20 min 400 min Load 20 A No No 7 min 13 min 240 min 6 LAY OUT AND CONNECTIONS 7 INPUT AND OUTPUT LOAD AND BATTERY CONNECTION...

Page 5: ...wer 2 See Diagnosis Led 8 1 4 Relay Contact Rating Max DC1 30 Vdc 1 A AC1 60 Vac 1A Resistive load EN 60947 4 1 Min 1mA at 5 Vdc Min permissive load 8 1 5 Charging Mode STATUS Status Led Diagnosis No...

Page 6: ...Acid Gel Ni Cd option They guarantee battery reliability in time by continuously testing the internal impedance status avoids any possible risk of damages and grants a permanent reliable and safe conn...

Page 7: ...er Position Size 1 Jumper Position Size 2 Jumper Position Size 3 Dip Switch Position Size 4 Float charge Volt Cell Fast charge Volt Cell Open Lead 2 23 2 40 AGM Low 2 25 2 40 Gel Battery 2 30 2 40 NiC...

Page 8: ...he quality resistance on the battery connection is checked every 60 sec This to detect if the cable connection has been properly made Battery in Open Circuit or Sulphated In Float charging mode the Al...

Page 9: ...STICS The unit is a SLAVE in a MODBUS network The slave units are compliant to the following specifications Transmission mode MODBUS RTU Electrical Interface RS485 half duplex serial line Baud rate 48...

Page 10: ...onnection Diagram Size3 CBI500 DPYCONN500 is a special cable for the connection of CBI Size3 and the other device max leght 0 5m RJ45COUPLER is e T connection RJ45 for daisy Chain with CBI Size3 RJCON...

Page 11: ...ections to the external device like RTU PC DPY351 For the connection to RTU PLC or similar devices refer to the instruction manuals Modbus specifications_R14 Web Site www adelsystem com For configurat...

Page 12: ...ity to EN60950 UL60950 1 and CSA C22 2 No 60950 1 07 Information Technology Equipment Safety Part1 General Requirement Device is intended to be installed in a cabinet protected from external shocks or...

Reviews: