11 STANDARD AND CERTIFICATIONS 

11.1.1 Electrical Safety for Mounting: 

Device assembling: UL508, IEC/EN 60950 (VDE 0805) and EN 50178 (VDE 0160). Installation according: 
IEC/EN 60950. Input / Output separation: SELV EN 60950-1 and PELV EN 60204-1. Double or reinforced 
insulation. Safety of Electrical Equipment Machines: EN 60204-1. 

 In According to EMC 2014/30/UE and Low voltage directive 2014/35/UE 

11.1.2 Safety Standards:  

EN IEC 62368-1: 2014/AC:2015 

11.1.3 EMC Standards Immunity: 

EN 61000-4-2, EN 61000-4-3, EN 61000-6-2, EN 61000-4-4, EN 61000-4-5. 

11.1.4 EMC Standards Emission: 

EN 61000-6-4, EN 61000-6-3, EN 61000-3-2 (see data sheet for each device) 

11.1.5 Conformity to:  

EN60950/UL60950-1  and  CSA  C22.2  No.  60950-1-07  (Information  Technology  Equipment)  –  Safety  – 
Part1: General Requirement. 

 

Device is intended to be installed in a cabinet protected from external shocks or damages.  
Electrical safety EN54-4 Fire Detection and fire alarm systems  
DIN41772: Charging curve; DIN41773: Characteristic Curve for charging Lead Acid and Nickel-Cadmium 
batteries. 

11.1.6 Approved:  

Devices,  CBI243A,  CBI245A,  CBI123A,  CBI126A,  CBI1210A,CBI2410A  and\S,  CBI485A  and  \S, 
CBI1235A, CBI2420A, CBI4810A 
EN60950 / UL60950-1 and CSA C22.2 No. 60950-1-07 (Information Technology Equipment) – Safety – 
Part1: General Requirement. 

 

12    RAIL MOUNTING: 

All  modules  must  have  a  minimum  vertical  and  horizontal  distance  of  10  cm  to  this  power 
supply  in  order  to  guarantee  sufficient  auto  convection.  Depending  on  the  ambient 
temperature and load of the device, the temperature of the housing can become very high. 

 
 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for ALL IN ONE CBI Series

Page 1: ...y efficiency reduces risk of battery damage and allows a safe operation in permanent connection Predefined curves can be selected by jumpers or DIP switch to optimize the charge of different battery t...

Page 2: ...or Load DC Bus one Input Output for connection to the battery N 1 battery 12 Vdc for CBI 12xx N 2 battery 12 Vdc connected in Series for CBI 24xx N 4 battery 12 Vdc connected in Series for CBI 48xx 5...

Page 3: ...installation clearance of 10 mm left right between two power supplies and avoid installing the power supplies on top of each other Note Avoid return voltage e g from a decelerating motor or battery w...

Page 4: ...45 min 20 h Load 12 A No 3 min 12 min 30 min 600 min Load 15 A No No 9 min 20 min 400 min Load 20 A No No 7 min 13 min 240 min 6 LAY OUT AND CONNECTIONS 7 INPUT AND OUTPUT LOAD AND BATTERY CONNECTION...

Page 5: ...wer 2 See Diagnosis Led 8 1 4 Relay Contact Rating Max DC1 30 Vdc 1 A AC1 60 Vac 1A Resistive load EN 60947 4 1 Min 1mA at 5 Vdc Min permissive load 8 1 5 Charging Mode STATUS Status Led Diagnosis No...

Page 6: ...Acid Gel Ni Cd option They guarantee battery reliability in time by continuously testing the internal impedance status avoids any possible risk of damages and grants a permanent reliable and safe conn...

Page 7: ...er Position Size 1 Jumper Position Size 2 Jumper Position Size 3 Dip Switch Position Size 4 Float charge Volt Cell Fast charge Volt Cell Open Lead 2 23 2 40 AGM Low 2 25 2 40 Gel Battery 2 30 2 40 NiC...

Page 8: ...he quality resistance on the battery connection is checked every 60 sec This to detect if the cable connection has been properly made Battery in Open Circuit or Sulphated In Float charging mode the Al...

Page 9: ...STICS The unit is a SLAVE in a MODBUS network The slave units are compliant to the following specifications Transmission mode MODBUS RTU Electrical Interface RS485 half duplex serial line Baud rate 48...

Page 10: ...onnection Diagram Size3 CBI500 DPYCONN500 is a special cable for the connection of CBI Size3 and the other device max leght 0 5m RJ45COUPLER is e T connection RJ45 for daisy Chain with CBI Size3 RJCON...

Page 11: ...ections to the external device like RTU PC DPY351 For the connection to RTU PLC or similar devices refer to the instruction manuals Modbus specifications_R14 Web Site www adelsystem com For configurat...

Page 12: ...ity to EN60950 UL60950 1 and CSA C22 2 No 60950 1 07 Information Technology Equipment Safety Part1 General Requirement Device is intended to be installed in a cabinet protected from external shocks or...

Reviews: