IRIS-4 Technical Reference Manual.docx 12/01/2023
page 41
6.13.5.4
Default CID Set/Restore event codes
6.14
Relays
This option lets you configure the relays.
Relay input follower
This feature lets the terminal relay outputs be set to follow a pin input, with a
delay if required. Normally a relay will open if the associated input goes open
circuit, and vice-versa, but this can be inverted if required.
Note: Do not use this feature for a relay with another purpose, e.g., communications path trouble reporting.
Relay SMS activation
The terminal lets each relay be activated or deactivated with a predefined SMS
message from a mobile phone.
6.14.2.1
Phone number
This option sets which calling device (mobile phone) may control the relay with
the relevant SMS message. This is done by using the Calling Line Number (CLI)
on the SMS and comparing this with the number entered.
Pin no.
CID event
code
Group
no.
Zone
no.
CID event description
1
110
00
001
Fire alarm zone 1
2
120
00
002
Panic alarm zone 2
3
130
00
003
Burglary alarm zone 3
4
400
00
004
Open/Close zone 4
5
300
00
005
System Trouble zone 5
6
573
00
006
Burglary bypass zone 6
7
139
00
007
Intrusion verifier zone 7
8
137
00
008
Tamper alarm zone 8
9
301
00
009
AC Power trouble zone 9
10
380
00
010
Sensor trouble zone 10
11
101
00
011
Personal emergency alarm
zone 11
12
302
00
012
Low system battery zone 12
13
100
00
013
Medical alarm zone 13
14
323
00
014
Alarm relay zone 14
15
323
00
015
Alarm relay zone 15
16
323
00
016
Alarm relay zone 16