page 36
IRIS-4 Technical Reference Manual.docx 12/01/2023
Eth 2
This allows you to set up the second Ethernet port for the Vanderbilt (Siemens)
SPC integration. For more information see alarm panel specific documentation
available from AddSecure.
6.10
Alarm override
This lets you set the terminal to override the alarm panel's account number and
dialed number with those set in the terminal.
6.11
Extra features
This allows you to set up the special options for the terminal.
Normal
This is the default mode for a terminal.
Set / unset
In a normal alarm installation, the terminal is used with an attached alarm panel.
However, if the requirements for monitoring are simple, requiring only a few
alarm events like set & unset or entry / exit alarms (e.g., ATM monitoring), the
terminal can be set up to be a simple alarm panel using the pin inputs.
6.11.2.1
Set / unset pin
Configuration options for the Set/Unset pin.
6.11.2.1.1
Pin number
Allocate which pin is for the set and unset signals.
6.11.2.1.2
Trigger mode
This sets the trigger mode to “normal”, which means that the unit is unset when
the input pin is “open circuit”. This method is suitable for an external physical
switch such as a key-switch.
The trigger mode can be set to “pulse”, which means that a pulse on the
set/unset input toggles the set/unset status. This is suitable for an external device such as a proximity tag
reader.
6.11.2.2
Exit delay
This option lets you set the exit delay timer. The default is 10 seconds.
6.11.2.3
Entry Pin
This option lets you allocate which pin is to be used for the entry signal.