ADCP-61-819
•
Issue 1
•
July 2000
Page 6
© 2000, ADC Telecommunications, Inc.
3
INSTALLATION
3.1 Redundant Amplifier Switch Installation
Warning
:
Never install video equipment in a wet location or during a lightning storm
.
Use the following procedure to install and cable the Redundant Amplifier Switch in a 19-inch
network rack, or equivalent. Panel dimensions are shown in the front and top views in
1. At the designated rack location, align the mounting holes in the switch mounting ears
with the threaded holes in the rack, then mount the redundant switch on the rack with
four #12-24 screws. (See
Figure 5
.)
15029-A
Figure 5. Installing the Redundant Switch in Rack
2. Using AWG 18 (or larger) stranded wire; connect the frame ground to the frame ground
screw in the lower left corner of the rear panel (see