I. A SPECIAL THANK YOU

Congratulations on your purchase of an ADC® Advantage™ Automatic Blood Pressure
Monitor.

In hospitals and physician's offices throughout the world, where accuracy and
dependability are critical, ADC® professional diagnostic products are the instruments of
choice.

Now you, too, can enjoy the benefits of ADC® engineering and quality in the home. This
feature rich instrument was designed to simplify the measurement of blood pressure and
pulse rate at home and deliver consistent, dependable results.

Read this booklet thoroughly before attempting to use your new ADC® Advantage™
Automatic Blood Pressure Monitor.

1. INTRODUCTION AND INTENDED USE

This manual is for Advantage™ Semi-Automatic Blood Pressure Monitor (6012N).

Your ADC

®

Advantage™ blood pressure monitor is a semi-automatic digital blood pressure

measuring device for use on the upper arm. It enables very fast and reliable measurement
of the systolic and diastolic blood pressure as well as the pulse by way of the oscillometric
method. This device offers clinically proven accuracy and has been designed to be user
friendly.

Read this booklet thoroughly before attempting to use your new ADC

®

Advantage™ Semi-

Automatic Blood Pressure Monitor.

Remember…

Only a healthcare professional is qualified to interpret blood pressure measurements.

This device is NOT intended to replace regular medical checkups.

It is recommended that your physician review your procedure for using this device.

Blood pressure readings obtained by this device should be verified  before prescribing or

making adjustments to any medications used to control hypertension.  Under no
circumstances should YOU alter the dosages of any drugs prescribed by your doctor.

This monitor is intended for use by adults only. Consult with a physician before using

this instrument on a child.

In cases of irregular heartbeat (Arrhythmia), measurements made with this instrument

should only be evaluated after consultation with your doctor.

Familiarize yourself with the section titled "About Blood Pressure". It contains important

information on the dynamics of blood pressure readings and will help you to obtain the
best results.

2. WARNINGS AND PRECAUTIONS

Warning: 

The device contains sensitive electronic components. Avoid strong electrical or

electromagnetic fields in the direct vicinity of the device (e.g., mobile telephones, microwave

ovens). These can lead to temporary impairment of the measuring accuracy.

Warning: 

Use of this instrument on patients under dialysis therapy or on anticoagulant,

antiplatelets, or steroids could cause internal bleeding.

Warning:

Do not use cuffs, AC adapters or batteries other than those included with this

product or replacement parts supplied by the manufacturer

.

Summary of Contents for Advantage 6012N

Page 1: ...Directions for Use ADC 6012N AdvantageTM Semi Automatic Blood Pressure Monitor...

Page 2: ...lified to interpret blood pressure measurements This device is NOT intended to replace regular medical checkups It is recommended that your physician review your procedure for using this device Blood...

Page 3: ...Your level of blood pressure is determined in the circulatory center of the brain and adjusts to a variety of situations through feedback from the nervous system To adjust blood pressure the strength...

Page 4: ...as volatile diastolic pressure can still vary significantly In hypertensive individuals variations are even more pronounced Normally blood pressure is at its lowest during sleep and rises in the morni...

Page 5: ...ults of any one measurement Individual results may be influenced by spiking of your pressure due to diet anxiety or mis measurement resulting from excessive arm movement or misapplication of the cuff...

Page 6: ...ow at least 5 minute intervals between measurements Discard any reading that appears suspect and record the average of the remaining readings If this method is used be sure to note that the readings a...

Page 7: ...same time of day since blood pressure changes during the course of the day Measurements should be done after 5 minute rest to ensure accuracy 6 1 Fitting the Cuff Position the cuff flat on the table w...

Page 8: ...to a higher pressure see Inflating Further in section 6 4 When the device detects a pulse a heart symbol in the display starts to flash and a beep is heard for every heartbeat 6 3 Reading Measurement...

Page 9: ...ntly e g several times per week on measurements performed daily we recommend the patient to seek medical advice The instrument does not replace a cardiac examination but serves to detect pulse irregul...

Page 10: ...if the display is unusual then exchange them for new ones Check the connection of the cuff tube and connect properly 1 Fit the cuff correctly on the arm 2 Beforestartingmeasurementmakesurethatclothin...

Page 11: ...the manufacturer s warranty Note According to international standards your monitor should be checked for calibration every 2 years Contact ADC for an accuracy check 10 TECHNICAL SPECIFICATIONS Weight...

Page 12: ...is registered online at www adctoday com 12 QUALITY STANDARDS Device standard This device is manufactured to meet the European and United States standards for non invasive blood pressure monitors EN10...

Reviews: