9. CARE AND MAINTENANCE

Do not expose the device to either extreme temperatures, humidity, dust or
direct sunlight.

Handle the cuff carefully and avoid all types of stress through twisting or
buckling in order not to damage the sensitive air-tight bubble.

Clean the device with a soft, dry cloth. Do not use gas, thinners or similar
solvents. Spots on the cuff can be removed carefully with a damp cloth and
soapsuds. Do not submerge the cuff in water!

Handle the tubing carefully.
Keep the tube away from sharp edges.

Do not drop the monitor or treat it roughly in any way.

Never open the monitor!
This invalidates the manufacturer’s warranty.

Note:

According to international standards, your monitor should be checked for calibration every 2

years. Contact ADC for an accuracy check.

10. TECHNICAL SPECIFICATIONS

Weight:                                  

.96 lbs. (436 g) (with bat cuff)

Size:                                       

3.75” x 4.25” x 5.5”

                                                    85mm x 77mm x 140mm (including cuff)

Storage temperature:            

23°F−122°F (–5°C− +50°C)

Humidity:                               

15 to 85% relative humidity maximum

Operation temperature:         

50°F−104°F (10°C−40°C)

Display:                                 

LCD  (Liquid Crystal Display)

Measuring method:               

Oscillometric

Pressure sensor:                   

Capacitive

Measuring ranges

SYS/DIA Pressure:                 

SYS/DIA: 30 to 280 mmHg

Pulse:                                     

40 to 200 beats per minute

Cuff pressure display range:    

0-299 mmHg

Memory:                                

Automatically stores the last measurement.

Measuring resolution:           

1 mmHg

Accuracy:                               

Pressure within ± 3 mmHg or 2% of

                                                    the reading 

200mmHg

                                                    Pulse ± 5 % of the reading

Summary of Contents for Advantage 6012N

Page 1: ...Directions for Use ADC 6012N AdvantageTM Semi Automatic Blood Pressure Monitor...

Page 2: ...lified to interpret blood pressure measurements This device is NOT intended to replace regular medical checkups It is recommended that your physician review your procedure for using this device Blood...

Page 3: ...Your level of blood pressure is determined in the circulatory center of the brain and adjusts to a variety of situations through feedback from the nervous system To adjust blood pressure the strength...

Page 4: ...as volatile diastolic pressure can still vary significantly In hypertensive individuals variations are even more pronounced Normally blood pressure is at its lowest during sleep and rises in the morni...

Page 5: ...ults of any one measurement Individual results may be influenced by spiking of your pressure due to diet anxiety or mis measurement resulting from excessive arm movement or misapplication of the cuff...

Page 6: ...ow at least 5 minute intervals between measurements Discard any reading that appears suspect and record the average of the remaining readings If this method is used be sure to note that the readings a...

Page 7: ...same time of day since blood pressure changes during the course of the day Measurements should be done after 5 minute rest to ensure accuracy 6 1 Fitting the Cuff Position the cuff flat on the table w...

Page 8: ...to a higher pressure see Inflating Further in section 6 4 When the device detects a pulse a heart symbol in the display starts to flash and a beep is heard for every heartbeat 6 3 Reading Measurement...

Page 9: ...ntly e g several times per week on measurements performed daily we recommend the patient to seek medical advice The instrument does not replace a cardiac examination but serves to detect pulse irregul...

Page 10: ...if the display is unusual then exchange them for new ones Check the connection of the cuff tube and connect properly 1 Fit the cuff correctly on the arm 2 Beforestartingmeasurementmakesurethatclothin...

Page 11: ...the manufacturer s warranty Note According to international standards your monitor should be checked for calibration every 2 years Contact ADC for an accuracy check 10 TECHNICAL SPECIFICATIONS Weight...

Page 12: ...is registered online at www adctoday com 12 QUALITY STANDARDS Device standard This device is manufactured to meet the European and United States standards for non invasive blood pressure monitors EN10...

Reviews: