Description
3.5 Components
For the exact location and connectors see § 3.4 and the electrical scheme. You can find the electrical
scheme attached on the outside of the equipment.
3.5.1
Line input
Input terminal, all cabinets
The input terminal connects the power input cables to the
equipment.
Line filter, all cabinets
The line filter blocks the noise the equipment generates to the
line input and filters out voltage pulses from the input voltage.
Manual switch, all cabinets
The manual switch is a magneto-thermal switch that connects
the mains power supply to the equipment. You can manually set
the switch to the ON or OFF position.