206
Software Installation and User’s Guide
Advanced Features
Advanced Features
B
B.1
Chaining
The ICP RAID firmware supports Drive Chaining (also referred to as Disk Spanning).
Drive Chaining is the process of linking several individual drives to form a large single
drive. Chaining is only available after having selected two or more drives in the ICP
RAID Console or ICP RAID Navigator.
Warning:
Using logical drives of the type
chain
as components of array drives is not
recommended.
Warning:
Disk Chaining does not offer any form of data protection.
B.1.1
Configuring a Chaining Set Using ICPCON
1. Select
Create New Host Drive
.
2. Select 2 or more drives.
3. Press Enter and select
Chaining
.
B.1.2
Configuring a Chaining Set Using ICP RAID Navigator
1. Click on the
New host drive
icon.
2. Select the
Configuration
menu, then
Host Drive, Create New
. A new host drive
window appears.
3. Select a drive(s) using <Shift> and arrow keys.
Chaining
is greyed out before selecting
2 drives and is available after selecting 2 drives.
4. Select
Chaining
and press Enter.
The system will configure the chain set that is now a logical drive.
Summary of Contents for 2074700-R - ICP Vortex GDT8514RZ RAID Controller
Page 1: ...Preliminary ICP RAID Software Software Installation and User s Guide Version 1 2 7 June 2003 ...
Page 23: ...Software Installation and User s Guide 23 Introduction ...
Page 68: ...68 Software Installation and User s Guide Installing Linux ...
Page 92: ...92 Software Installation and User s Guide Installing Berkeley UNIX FreeBSD ...
Page 214: ...214 Software Installation and User s Guide Fibre Channel Features ...