114
Software Installation and User’s Guide
ICP RAID Console
the migration of host drives between ICP RAID controllers is very easy and secure, even
if the SCSI IDs and channels are changed. Simply connect the hard disks to the new ICP
RAID controller, and the host drives will be automatically available.
10.5.1.2
Firmware Update
From the Advanced Setup menu, select the
Configure Controller
option and press Enter to
display the Configure Controller menu, then select the
Firmware Update
option and press
Enter to begin the process for updating the firmware.
Firmware Update
allows you to update the firmware, controller BIOS, and XROM
ICPCON currently programmed on the flash memory of the ICP RAID controller.
Because the Flash-RAM can be reprogrammed many times, the software modules can be
easily updated, without having to remove the controller from its PCI slot.
The firmware, controller BIOS, and XROM ICPCON are part of the file,
SRC_RXFW.xxx, where the file extension xxx indicates the version stepping. There is a
firmware file on the RAID Software Suite CD-ROM. To get the latest firmware for the
ICP RAID controller, visit our web site at: http://www.icp-vortex.com or http://
www.vortex.de.
Note:
The
Firmware Update
option is not available when ICPCON is accessing the ICP RAID
controller remotely.
Follow the procedure below to update the firmware via XROM ICPCON or the OS
version of ICPCON.
1. Format a 3.5” HD disk (1.44MB) and copy the SRC_RXFW file onto the disk. Obtain
the SRC_RXFW file from the RAID Software Suite CD-ROM, or if necessary,
download the firmware image containing the latest programs/drivers from the web
site.
2. Launch ICPCON, select the applicable ICP RAID controller and press Enter.
3. If the
Express Setup
menu is displayed, press <F4> to display the A
dvanced Setup
menu. Select the menu option,
Configure Controller
and press Enter. Insert the floppy
containing the latest firmware file into the floppy disk drive.
4. From the Configure Controller submenu, select
Firmware Update
and press Enter.
5. XROM ICPCON automatically searches for the firmware file from the floppy drive,
a:\.
The OS version of ICPCON asks for the path to the file (see
Figure 10-59
). Type in the
path to the floppy drive and press Enter.
After finding the file, ICPCON displays the name, description and version of the
firmware. Press Enter.
Summary of Contents for 2074700-R - ICP Vortex GDT8514RZ RAID Controller
Page 1: ...Preliminary ICP RAID Software Software Installation and User s Guide Version 1 2 7 June 2003 ...
Page 23: ...Software Installation and User s Guide 23 Introduction ...
Page 68: ...68 Software Installation and User s Guide Installing Linux ...
Page 92: ...92 Software Installation and User s Guide Installing Berkeley UNIX FreeBSD ...
Page 214: ...214 Software Installation and User s Guide Fibre Channel Features ...