Software Installation and User’s Guide
135
ICP RAID Console
copying is finished, you can remove the critical logical drive and then carry out a hot plug
procedure. You can also use this function to mirror RAID 4/5 array drives (RAID 5+1,
RAID 4+1).
Replace Array Component
Note:
The Replace Array Component option is not available for RAID 1 and RAID 10 volumes
if you are manually hot swapping drives. Instead, use the Repair Array Drives option on
the main menu in the ICP RAID Console, or use the Add RAID1 Component option under
the Configure Logical Drives menu.
To access this function, from the Advanced Setup menu:
•
Select the
Configure Array Drives
option and press Enter to display the Select Array
Drive screen.
•
Select an array drive and press Enter to display the Array Drive window.
•
Select the
Replace Array Component
option and press Enter.
If a logical drive of an array drive without a hot fix drive should fail (or is likely to fail),
you should replace the defective hard disk with a new one as soon as possible because the
array drive is without redundancy. The replacement logical drive has to have at least the
same capacity as the failed one. After you replace the hard disk, ICPCON offers a list of
existing physical drives which can be used as replacement units. The array drive's state
changes into
rebuild
and the missing data is automatically reconstructed on the new drive.
Remove RAID 1 Component
This option corresponds to the
Add RAID-1 Component
option. It allows you to remove a
previously configured RAID-1 combination.
To access this function, from the Advanced Setup menu:
•
Select the
Configure Array Drives
option and press Enter to display the Select Array
Drive screen.
•
Select an array drive and press Enter to display the Array Drive window.
•
Select the
Remove RAID 1 Component
option and press Enter.
After you choose the
Remove RAID 1 Component
option, ICPCON displays a warning
message to confirm the removal (see
Figure 10-86
). Press <Y> to proceed with the
removal of the selected RAID 1 Component, or press <N> to cancel the operation.
Figure 10-86. Remove Drive Confirmation
Remove Array Drive
Use the
Remove Array Drive
command to remove an existing array drive.
To access this function, from the Advanced Setup menu:
•
Select the
Configure Array Drives
option and press Enter to display the Select Array
Drive screen.
Summary of Contents for 2074700-R - ICP Vortex GDT8514RZ RAID Controller
Page 1: ...Preliminary ICP RAID Software Software Installation and User s Guide Version 1 2 7 June 2003 ...
Page 23: ...Software Installation and User s Guide 23 Introduction ...
Page 68: ...68 Software Installation and User s Guide Installing Linux ...
Page 92: ...92 Software Installation and User s Guide Installing Berkeley UNIX FreeBSD ...
Page 214: ...214 Software Installation and User s Guide Fibre Channel Features ...