Condenser Fan Replacement
Condenser Fan Replacement
Condenser Fan Replacement
Condenser Fan Replacement
Both the condenser fans should run whenever the compressor is running.
To replace either of the 2 condenser fans the front grille will need to be removed
(Chapter 8).
Depending on which fan has failed you will need to disconnect the Earth, Neutral &
Live wires from the connectors on the Condenser Fan. Then remove the 4 off M4x45
screws and remove the fan
(figure 24).
Reverse this procedure to replace the fan ensuring that all the wires are reconnected.
4 Off M4 X45 Br.Zn.Pd. Screws