CAUTION: if the amount of liquid dispensed is less than 5 litres, the device
will not allow calibration and will display an error.
For confirmation, the last quantity dispensed will be displayed flashing in the
current Unit of measurement
Icrease or decrease this quantity by pressing
or
until the correct
value is reached. Wait 10 seconds for the new calibration to be automati-
cally confirmed. With the new calibration the litres will be displayed on the
“Partial” screen and in the last 5 refuelling operations carried out they will be
adapted to the new calibration. The general total and the period total re-
main unchanged.
6.3 Selecting the unit of measurement
The system has 4 standard units of measurement (Litres-US Gallons-Quarts and Pints) plus one “Custom” unit that can be
configured by the user. How to select the unit of measurement: On the “Partial” screen do not press any key for 10 seconds.
1. Press
to enter Unit of measurement mode where the word “Unit” is displayed.
2.Press
to confirm.
3.Press
to scroll through the units of measurement available: “litres”- “us-gal” –“quarts” –
“pints” – “custom”.
4. Press
to confirm.
18
18
16
16
14
14
12
12
16 18,5
16 18,5
6.4 Custom unit of measurement
The CUSTOM unit of measurement is factory set at a decalitre (10 litres). This value can be set by the customer as follows:
Repeat the operations from point 1 to point 5 in paragraph 3.5.3 “Selecting the unit of measurement”. When the meter has con
-
firmed the custom unit of measurement with
, it will propose the flashing default value of
0.100. To obtain this coefficient, simply follow the custom/litre operation. E.g. if you wish to obtain a custom unit (1.00) for every
0.33 litre can, divide 1/0.33= 3.03 and enter this new coefficient. Increase or decrease this value by pressing
or
until
the desired value has been reached, bearing inmind that the reference unit of
measurement is in litres. Once the set value is displayed, wait 10 seconds without pressing any key for the meter to confirm.
6.5 Factory reset
The factory reset procedure can only be performed by qualified personnel. If this operation needs to be
carried out, contact technical support (Chap. 11).
that the flow rate per minute is more than 10 litres and that, while dispensing, it is not topped up as cali
-
bration would be inaccurate. Fully open the nozzle. If the amount displayed does not match the measured
quantity, the meter must be calibrated.
Press
to enter Calibration mode where the word “CAL” is displayed.