background image

EXPLODED VIEWS

G FLOW DISPLAY - PULSE OUT

25

24

3

14

15

20

7

8

6

5

23

1

10

9

4

11

16

2

17

22

21

19

18

13

26

27

Num. 

articolo Num. parte Descrizione

Quantità

1

TF066

CORPO CONTALITRI G-FLOW

1

2

TF065

FLANGIA CHIUSURA CONTALITRI INGRANAGGI

1

3

VT040

Vite TC Croce M5x12 Trilobata UNI 8112

4

4

OR011

O-RING 37 x 3 NBR

4

5

VT039

VITE TCCE M8X16 ZNB ISO 4762 

4

6

TF070

SPINA CEMENTATA PER G-FLOW 5X60

2

7

TF040

MAGNETE A DISCO d3x6 DI FLOW -  IN LINE

4

8

TF071

SPINA CEMENTATA PER G-FLOW 3X14

2

9

TF018

TAPPO CALIBRAZIONE 1/8" T.FLOW

1

10

11010100200 O-Ring 108 NBR

1

11

TF068

RUOTA OVALE G-FLOW

4

12

TF076

FILTRO A RETE INGRESSO G-FLOW

1

13

VT038

Vite TC Croce M4x35 Trilobata UNI 8112

4

14

VT036

RONDELLA D.4 PIANA NYLON (4X8X0.8)

2

15

VT037

Vite TC Croce M4x6 Trilobata UNI 8112

2

16

OR031

O-RING NBR70 60X2.62 TENUTA TF065 G-FLOW

1

17

OR032

GUARNIZIONE PIANA FUSTELLATA GFLOW 86X82

1

18

TF067

COVER DISPLAY G-FLOW

1

19

TF084

SCHEDA G-FLOW DISPLAY U. PULSI

1

20

TF077

SPINA CEMENTATA PER G-FLOW 5X12

2

21

OR034

GUARNIZIONE SAGOMATA COVER G-FLOW

1

22

TF073

PIASTRINO DI CHIUSURA G-FLOW DISPLAY

1

23

TF064

FLANGIA ALLUMINIO ATTACCO 1"G FORATA

2

24

VT013

VITE PER PLASTICA TC 3X8 BN13577 WN1412

3

25

MA093

MASCHERINA G-FLOW ADAM PUMPS

1

26

TF052

GOMMINO USCITA CAVO FLUSS. KB 6-8-12-3,5

1

27

CA012

CAVO 5 POLI + CONNETTORE PER U.PULSI

1

28

EL012

Scehda REED 

1

4

3

2

1

A

B

C

D

5

6

7

8

E

F

A

B

C

D

E

F

8

7

6

5

4

1

2

3

Proprietà della  ADAM  PUMPS  Spa   -  Senza autorizzazione scritta della stessa il presente disegno non potrà essere comunque utilizzato per la 

costruzione dell' oggetto rappresentato, nè venire comunicato a terzi o riprodotto. La società proprietaria tutela i propri diritti a rigore di legge.

Formato

A3

Codice

Denominazione

CONTALITRI G-FLOW DISPLAY

1:2

Scala

Materiale <non specificato>

Materiale

Revisioni

Rev.

RM n°

Data

Firma

V.Perrotta

Disegnato

02/12/2015

1

Data

Tolleranze generali

UNI EN 22768-mK

SW-Massa kg

Peso indicativo

02/12/2015

Data

Approvato

1 di 1

Foglio

2

3

4

6

8

5

7

9

GFG00S

Proprietà

- Componente Adam Pumps -

CODE 

DESCRIPTION 

QTY 

DISPLAY

PULSE OUT

TF066A 

TF066A 

METER BODY 

1

TF065A 

TF065A 

FLANGE 

1

VT040 

VT040 

SCREW TC M5x16 

4

OR011 

OR011 

O-RING 37 x 3 NBR 

4

VT045

VT045

SCREW TBEI M8X25 ZNB

 4

TF070 

TF070 

CEMENTED PIN 5X60 

2

TF040 

TF040 

MAGNET Ø3x6 

 4

TF071 

TF071 

CEMENTED PIN 3X14 

2

TF018 

TF018 

CALIBRATION KNOB 1/8” 

1

10 

11010100200 

11010100200 

O-RING 108 NBR 

1

11 

TF068 

TF068 

OVAL GEAR

4

12 

TF076 

TF076 

INLET FILTER

1

13 

VT038 

VT038 

SCREW TC M4x35 

4

14 

VT036 

VT036 

NYLON WASHER 

2

CODE 

DESCRIPTION 

QTY 

DISPLAY

PULSE OUT

15 

VT037 

VT037 

SCREW TC M4x6 

2

16 

OR031 

OR031 

O-RING NBR70 60X2.62 

1

17 

OR032 

OR032 

SEAL 86X82

1

18 

TF067 

TF067T 

COVER DISPLAY 

1

19 

TF046GF

TF084 

ELECTRONIC PCB

1

20 

TF077 

TF077 

CEMENTED PIN  5X12 

2

21 

OR034 

OR034 

SEAL 

1

22 

TF073

TF073

PLATE 

1

23 

TF064 

TF064 

FLANGE 1”G 

2

24 

VT013 

VT013 

SCREW TC 3X8 

 3

25 

MA093 

MA093 

FACEPLATE 

1

26 

 - 

TF052 

CABLE GLAND 

1

27 

 -

CA012 

CABLE 5 POLES

1

28

TF048

-

BATTERY AAA

2

28

Summary of Contents for G FLOW

Page 1: ... resistenza 46 48 41011 Campogalliano MO ITALIA Tel 39 059 528128 Fax 39 059 528437 www adampumps com info adampumps com UM021 7 2020 rev 5 G FLOW G FLOW PULSI G FLOW REED ITALIANO lingua originale ENGLISH translation of original instructions IT EN ...

Page 2: ...a justified request from ADAM PUMPS S p a or by sending a request to info adampumps com The person authorised to compile the technical file and draw up the declaration is Davide Stassi as legal representative Place and date of the document Campogalliano January 14 2020 The legal representative TABLE OF CONTENTS 1 GENERAL WARNINGS 2 SAFETY INSTRUCTIONS 2 1 Safety measures 2 2 First aid 2 3 Protecti...

Page 3: ... All rights under these rules belong to ADAM PUMPS S p A reproduction even partial of this manual its publication modification transcription public disclosure distribution marketing in any form translation and or development loan or any other activity reserved by law to ADAM PUMPS S p A 2 3 Protective devices Protective equipment characteristics Wear equipment that is appropriate for the operation...

Page 4: ...WATER The LCD display on the G FLOW has a numerical register and different instructions that are displayed only when appropriate 1 Partial register total register and instructions ALERT STOCK and PARTIAL TOTALISER 2 Flat battery indicator 3 TOTAL key 4 RESET key The regular shape of the G FLOW meter allows the LCD display mask to rotate in 90 steps To rotate the LCD screen 1 Unscrew the 4 screws h...

Page 5: ... screens The device automatically switches on when dispensing starts or when either the Reset key R or the Total key T is pressed once The display automatically switches off if no operation is performed or if no signal is detected for 120 consecutive seconds Each time the meter is switched off the Partial screen is reset therefore it does not need resetting at the first refuelling after switch off...

Page 6: ...ispensedinacertainperiodoftime Thisnumber canberesetbypressing Access by pressing Displaying 5 digits no decimal point shows the remaining stock in the storage tank To set this stock go to the Stock screen and press The value displayed will start flash ing and can then be changed as required by pressing to increase it or o decrease it To quickly increase or decrease it press and hold or To confirm...

Page 7: ... signals a Stock alert To set this stock go to the Alert screen and press The value displayed will start flashing and can then be changed as required by pressing to increase it or to decrease it To quickly increase or decrease it press and hold or To confirm wait 10 seconds without pressing any key until the meter automatically returns to the Partial screen NOTE The alert is disabled if 0 is set 6...

Page 8: ... 14 14 12 12 16 18 5 16 18 5 6 4 Custom unit of measurement The CUSTOM unit of measurement is factory set at a decalitre 10 litres This value can be set by the customer as follows Repeat the operations from point 1 to point 5 in paragraph 3 5 3 Selecting the unit of measurement When the meter has con firmed the custom unit of measurement with it will propose the flashing default value of 0 100 To ...

Page 9: ...ctor pul l CAL 40 00 5 Supply voltage in Volts bat Vol 2 79 if the value is than 2 8V otherwise the word FULL is dis played 6 Remaining battery charge percentage bat Per 52 95 displayed only if the supply voltage is 2 8 Volt If the supply voltage reaches 1 5 Volt the battery symbol will appear flashing on the bottom right Below 0 6V the display will no longer be visible and the batteries will have...

Page 10: ...l on the product and or on the packaging is not to be disposed of with unsorted municipal waste The symbol indicates that this product must not be disposed of with normal household waste It is the responsibility of the owner to dispose of these products and the other electrical and electronic equipment through specific collection facilities appointed by the government or by local authorities 10 WA...

Page 11: ...in general 11 TECHNICAL SUPPORT The Manufacturer is always available for any information required on installation operation or maintenance of the machine The Customer should ask the questions clearly with reference made to this Manual and to the instructions listed Always remember to specify the type of product and the production date on the label under the LCD display mask G Flow display version ...

Page 12: ...i 70 994 70 994 70 994 Precision 0 3 0 3 0 5 Repeatability 0 2 0 2 0 2 Display rotation Complete with 90 steps Input Output BSP G Flange 1 F Flange 1 F Flange 1 F Body material Aluminium Aluminium Aluminium Gear material POM C POM C POM C O Ring material NBR NBR NBR Other materials in contact with the fluid Brass Steel NdFe Brass Steel NdFe Brass Steel NdFe Min max operating temperature C 10 60 10...

Page 13: ...1 Data Tolleranze generali UNI EN 22768 mK SW Massa kg Peso indicativo 02 12 2015 Data Approvato Proprietà Componente Adam Pumps CODE DESCRIPTION QTY DISPLAY PULSE OUT 1 TF066A TF066A METER BODY 1 2 TF065A TF065A FLANGE 1 3 VT040 VT040 SCREW TC M5x16 4 4 OR011 OR011 O RING 37 x 3 NBR 4 5 VT045 VT045 SCREW TBEI M8X25 ZNB 4 6 TF070 TF070 CEMENTED PIN 5X60 2 7 TF040 TF040 MAGNET Ø3x6 4 8 TF071 TF071 ...

Page 14: ...TF065A Cover 1 3 TF064 Inlet flange 2 4 OR011 O Ring 37 x 3 4 5 TF070 cemented pin 5x60 2 6 TF040 Magnet Ø3 4 7 TF071 cemented pin 3x14 2 8 TF018 calibration cap 1 8 1 9 11010100200 O Ring 108 1 10 TF068 oval wheel 4 11 OR033 O Ring 6 532 1 CODE DESCRIPTION QTY 12 TF076 Inlet filter 1 13 TF072 Cover plate 1 14 AC005 Cable gland 1 15 VT036 Nylon Washer 2 20 OR031 O Ring 2 142 1 17 TF077 cemented pi...

Reviews: