1 - GENERAL WARNINGS

2 - SAFETY INSTRUCTIONS

2.1 Safety measures

IMPORTANT: It is essential to have understood the entire instruction manual before 

performing any operation, so as to safeguard operator safety and to avoid potential product 

damage.

CAUTION

Live equipment.Contact between the power supply and the liquid to be pumped must be 

prevented at all costs. Connect all equipment in the work area to the earthing system. Immediately stop 

operation in the event of electrostatic discharges or if you feel a shock. Do not use this device until the 

problem has been identified and duly solved.

CAUTION

Flammable liquids.Observe the precautions against the risk of fire or explosion. Read 

the safety data sheets to know the specific hazards of the fluids used. If there are flammable liquids in 

the work area (petrol, glass cleaning liquids, etc.), you must be aware that the vapours produced can 

ignite and explode. Only use the product in well-ventilated areas to prevent fires and explosions. Do 

not connect or disconnect the power cables or turn the lights on and off in the presence of flammable 

vapours.

Storing the manual: 

This manual must be kept intact and fully legible. The end user and the skilled technicians 

authorised with installation and maintenance of the product in question must be able to consult it at all times.

Reproduction rights: 

This manual is the property of ADAM PUMPS S.p.A., which is the sole owner of all 

rights provided for by applicable law, including without limitation copyright rules. All rights under these rules belong 

to ADAM PUMPS S.p.A.: reproduction, even partial, of this manual, its publication, modification, transcription, public 

disclosure, distribution, marketing in any form, translation and/or development, loan, or any other activity reserved by 

law to ADAM PUMPS S.p.A.

2.3 Protective devices

Protective equipment characteristics: Wear equipment that is appropriate for the operations to be carried 

out. Wear equipment that is resistant to the products used

CAUTION: Dangerous liquids. Read the safety data sheets to know the specific hazards 

of the fluids used. When pouring dangerous liquids, always follow the safety measures 

provided by the liquid manufacturer. Keep dangerous liquids in approved containers and 

dispose of them in compliance with the applicable guidelines.

IMPROPER USE OF THE PRODUCT

Improper use can result in serious injury or death.

Do not operate the unit when fatigued or under the influence of alcohol or drugs.

Do not leave the work area while the product is powered or under pressure.

Turn all equipment off when not in use.

Do not blow compressed air through the meter.

Prevent liquids from drying inside the meter.

Do not alter or modify the product. Alterations or modifications to the product may invalidate the approvals and cause safety 

hazards.

Place the pipes and cables away from traffic, sharp edges, moving parts, and hot surfaces.

Do not twist or bend the hoses too much, do not move the product by the hoses.

Keep children and animals away from the work area.

Observe all of the safety regulations in force.

ALWAYS KEEP A WORKING FIRE EXTINGUISHER IN THE WORK AREA.

In case of contact with EYE, SKIN, INHALATION INGESTION and refer to the fluid OF SAFETY DATA used.

Summary of Contents for G FLOW

Page 1: ... resistenza 46 48 41011 Campogalliano MO ITALIA Tel 39 059 528128 Fax 39 059 528437 www adampumps com info adampumps com UM021 7 2020 rev 5 G FLOW G FLOW PULSI G FLOW REED ITALIANO lingua originale ENGLISH translation of original instructions IT EN ...

Page 2: ...a justified request from ADAM PUMPS S p a or by sending a request to info adampumps com The person authorised to compile the technical file and draw up the declaration is Davide Stassi as legal representative Place and date of the document Campogalliano January 14 2020 The legal representative TABLE OF CONTENTS 1 GENERAL WARNINGS 2 SAFETY INSTRUCTIONS 2 1 Safety measures 2 2 First aid 2 3 Protecti...

Page 3: ... All rights under these rules belong to ADAM PUMPS S p A reproduction even partial of this manual its publication modification transcription public disclosure distribution marketing in any form translation and or development loan or any other activity reserved by law to ADAM PUMPS S p A 2 3 Protective devices Protective equipment characteristics Wear equipment that is appropriate for the operation...

Page 4: ...WATER The LCD display on the G FLOW has a numerical register and different instructions that are displayed only when appropriate 1 Partial register total register and instructions ALERT STOCK and PARTIAL TOTALISER 2 Flat battery indicator 3 TOTAL key 4 RESET key The regular shape of the G FLOW meter allows the LCD display mask to rotate in 90 steps To rotate the LCD screen 1 Unscrew the 4 screws h...

Page 5: ... screens The device automatically switches on when dispensing starts or when either the Reset key R or the Total key T is pressed once The display automatically switches off if no operation is performed or if no signal is detected for 120 consecutive seconds Each time the meter is switched off the Partial screen is reset therefore it does not need resetting at the first refuelling after switch off...

Page 6: ...ispensedinacertainperiodoftime Thisnumber canberesetbypressing Access by pressing Displaying 5 digits no decimal point shows the remaining stock in the storage tank To set this stock go to the Stock screen and press The value displayed will start flash ing and can then be changed as required by pressing to increase it or o decrease it To quickly increase or decrease it press and hold or To confirm...

Page 7: ... signals a Stock alert To set this stock go to the Alert screen and press The value displayed will start flashing and can then be changed as required by pressing to increase it or to decrease it To quickly increase or decrease it press and hold or To confirm wait 10 seconds without pressing any key until the meter automatically returns to the Partial screen NOTE The alert is disabled if 0 is set 6...

Page 8: ... 14 14 12 12 16 18 5 16 18 5 6 4 Custom unit of measurement The CUSTOM unit of measurement is factory set at a decalitre 10 litres This value can be set by the customer as follows Repeat the operations from point 1 to point 5 in paragraph 3 5 3 Selecting the unit of measurement When the meter has con firmed the custom unit of measurement with it will propose the flashing default value of 0 100 To ...

Page 9: ...ctor pul l CAL 40 00 5 Supply voltage in Volts bat Vol 2 79 if the value is than 2 8V otherwise the word FULL is dis played 6 Remaining battery charge percentage bat Per 52 95 displayed only if the supply voltage is 2 8 Volt If the supply voltage reaches 1 5 Volt the battery symbol will appear flashing on the bottom right Below 0 6V the display will no longer be visible and the batteries will have...

Page 10: ...l on the product and or on the packaging is not to be disposed of with unsorted municipal waste The symbol indicates that this product must not be disposed of with normal household waste It is the responsibility of the owner to dispose of these products and the other electrical and electronic equipment through specific collection facilities appointed by the government or by local authorities 10 WA...

Page 11: ...in general 11 TECHNICAL SUPPORT The Manufacturer is always available for any information required on installation operation or maintenance of the machine The Customer should ask the questions clearly with reference made to this Manual and to the instructions listed Always remember to specify the type of product and the production date on the label under the LCD display mask G Flow display version ...

Page 12: ...i 70 994 70 994 70 994 Precision 0 3 0 3 0 5 Repeatability 0 2 0 2 0 2 Display rotation Complete with 90 steps Input Output BSP G Flange 1 F Flange 1 F Flange 1 F Body material Aluminium Aluminium Aluminium Gear material POM C POM C POM C O Ring material NBR NBR NBR Other materials in contact with the fluid Brass Steel NdFe Brass Steel NdFe Brass Steel NdFe Min max operating temperature C 10 60 10...

Page 13: ...1 Data Tolleranze generali UNI EN 22768 mK SW Massa kg Peso indicativo 02 12 2015 Data Approvato Proprietà Componente Adam Pumps CODE DESCRIPTION QTY DISPLAY PULSE OUT 1 TF066A TF066A METER BODY 1 2 TF065A TF065A FLANGE 1 3 VT040 VT040 SCREW TC M5x16 4 4 OR011 OR011 O RING 37 x 3 NBR 4 5 VT045 VT045 SCREW TBEI M8X25 ZNB 4 6 TF070 TF070 CEMENTED PIN 5X60 2 7 TF040 TF040 MAGNET Ø3x6 4 8 TF071 TF071 ...

Page 14: ...TF065A Cover 1 3 TF064 Inlet flange 2 4 OR011 O Ring 37 x 3 4 5 TF070 cemented pin 5x60 2 6 TF040 Magnet Ø3 4 7 TF071 cemented pin 3x14 2 8 TF018 calibration cap 1 8 1 9 11010100200 O Ring 108 1 10 TF068 oval wheel 4 11 OR033 O Ring 6 532 1 CODE DESCRIPTION QTY 12 TF076 Inlet filter 1 13 TF072 Cover plate 1 14 AC005 Cable gland 1 15 VT036 Nylon Washer 2 20 OR031 O Ring 2 142 1 17 TF077 cemented pi...