background image

22

13

14

11

19

18

20 12

18

9

1

8

3

17

2

15

21

4

4

20

5

7

10

6

24

Num. 

articolo

Num. parte

Descrizione

Quantità

1

TF066A

Corpo flussimetro

1

2

TF065A

Cover flussimetro

1

3

TF064

Flangia di ingresso flussimetro

2

4

OR011

O-RING 37 X 3 NBR

4

5

TF070

SPINA CEMENTATA PER G-FLOW 5X60

2

6

TF040

Magnete Ø3 L=6 mm

2

7

TF071

SPINA CEMENTATA PER G-FLOW 

3X14

2

8

TF018

TAPPO CALIBRAZIONE 1/8" T.FLOW

1

9

11010100200

O-Ring 108 NBR

1

10

TF068

RUOTA CONTALITRI AD INGRANAGGI 

OVALI

4

11

OR033

ORING 6-532 di 86, d2

1

12

TF076

Filtro ingresso flow meter

1

13

TF072

Lamiera di chiusura 

1

14

AC005

Pressacavo PG9

1

15

VT036

Rondella Nylon 4x8x0,8

2

20

OR031

ORING 2-142 Di 60 d 2.62

1

17

TF077

SPINA CEMENTATA PER G-FLOW 5X12

2

18

TF079

SCHEDA 1 REED IN-LINE + CAVO 2M

1

19

VT040

Vite TC Croce M5x12 Trilobata UNI 

8112

4

20

VT039

VITE TCCE M8X16 ZNB ISO 4762 

4

21

VT037

Vite TC Croce M4x6 Trilobata UNI 

8112

2

22

80901439100

Vite TC Croce M4x10 Trilobata UNI 

8112

4

24

Dado M8

Dado M3 esagonale 

autobloccante UNI 7473

1

4

3

2

1

A

B

C

D

5

6

7

8

E

F

A

B

C

D

E

F

8

7

6

5

4

1

2

3

Proprietà della  ADAM  PUMPS  Spa   -  Senza autorizzazione scritta della stessa il presente disegno non potrà essere comunque utilizzato per la 

costruzione dell' oggetto rappresentato, nè venire comunicato a terzi o riprodotto. La società proprietaria tutela i propri diritti a rigore di legge.

Formato

A3

Codice

Denominazione

CONTALITRI G-FLOW PULSI

1:2

Scala

Materiale <non specificato>

Materiale

Revisioni

Rev.

RM n°

Data

Firma

V.Perrotta

Disegnato

02/12/2015

1

Data

Tolleranze generali

UNI EN 22768-mK

760.40 kg

Peso indicativo

02/12/2015

Data

Ing.M.Dondi

Approvato

1 di 1

Foglio

2

3

4

6

8

5

7

9

Proprietà

- Componente Adam Pumps -

G FLOW REED SWITCH 

CODE 

DESCRIPTION 

QTY

TF066A 

Body 

1

TF065A

Cover 

1

TF064 

Inlet flange 

2

OR011 

O-Ring 37 x 3 

4

TF070 

cemented pin 5x60 

2

TF040

Magnet Ø3 

4

TF071 

cemented pin 3x14 

2

TF018  

calibration cap 1/8" 

1

9   11010100200 

O-Ring 108 

1

10  TF068  

oval wheel 

4

11  OR033 

O-Ring 6-532 

1

 

CODE 

DESCRIPTION 

QTY

12  TF076 

Inlet filter 

1

13  TF072 

Cover plate 

1

14  AC005 

Cable gland 

1

15  VT036 

Nylon Washer 

2

20  OR031 

O-Ring 2-142 

1

17 TF077  

cemented pin 5x12 

2

18  TF074 

reed GFlow card+cable  1

19  VT040  

screw M5x16

4

20  VT045 

screw M8X25 

4

21  VT037 

screw M4x6 

2

22   80901439100 

screw M4x10 

4

Summary of Contents for G FLOW

Page 1: ... resistenza 46 48 41011 Campogalliano MO ITALIA Tel 39 059 528128 Fax 39 059 528437 www adampumps com info adampumps com UM021 7 2020 rev 5 G FLOW G FLOW PULSI G FLOW REED ITALIANO lingua originale ENGLISH translation of original instructions IT EN ...

Page 2: ...a justified request from ADAM PUMPS S p a or by sending a request to info adampumps com The person authorised to compile the technical file and draw up the declaration is Davide Stassi as legal representative Place and date of the document Campogalliano January 14 2020 The legal representative TABLE OF CONTENTS 1 GENERAL WARNINGS 2 SAFETY INSTRUCTIONS 2 1 Safety measures 2 2 First aid 2 3 Protecti...

Page 3: ... All rights under these rules belong to ADAM PUMPS S p A reproduction even partial of this manual its publication modification transcription public disclosure distribution marketing in any form translation and or development loan or any other activity reserved by law to ADAM PUMPS S p A 2 3 Protective devices Protective equipment characteristics Wear equipment that is appropriate for the operation...

Page 4: ...WATER The LCD display on the G FLOW has a numerical register and different instructions that are displayed only when appropriate 1 Partial register total register and instructions ALERT STOCK and PARTIAL TOTALISER 2 Flat battery indicator 3 TOTAL key 4 RESET key The regular shape of the G FLOW meter allows the LCD display mask to rotate in 90 steps To rotate the LCD screen 1 Unscrew the 4 screws h...

Page 5: ... screens The device automatically switches on when dispensing starts or when either the Reset key R or the Total key T is pressed once The display automatically switches off if no operation is performed or if no signal is detected for 120 consecutive seconds Each time the meter is switched off the Partial screen is reset therefore it does not need resetting at the first refuelling after switch off...

Page 6: ...ispensedinacertainperiodoftime Thisnumber canberesetbypressing Access by pressing Displaying 5 digits no decimal point shows the remaining stock in the storage tank To set this stock go to the Stock screen and press The value displayed will start flash ing and can then be changed as required by pressing to increase it or o decrease it To quickly increase or decrease it press and hold or To confirm...

Page 7: ... signals a Stock alert To set this stock go to the Alert screen and press The value displayed will start flashing and can then be changed as required by pressing to increase it or to decrease it To quickly increase or decrease it press and hold or To confirm wait 10 seconds without pressing any key until the meter automatically returns to the Partial screen NOTE The alert is disabled if 0 is set 6...

Page 8: ... 14 14 12 12 16 18 5 16 18 5 6 4 Custom unit of measurement The CUSTOM unit of measurement is factory set at a decalitre 10 litres This value can be set by the customer as follows Repeat the operations from point 1 to point 5 in paragraph 3 5 3 Selecting the unit of measurement When the meter has con firmed the custom unit of measurement with it will propose the flashing default value of 0 100 To ...

Page 9: ...ctor pul l CAL 40 00 5 Supply voltage in Volts bat Vol 2 79 if the value is than 2 8V otherwise the word FULL is dis played 6 Remaining battery charge percentage bat Per 52 95 displayed only if the supply voltage is 2 8 Volt If the supply voltage reaches 1 5 Volt the battery symbol will appear flashing on the bottom right Below 0 6V the display will no longer be visible and the batteries will have...

Page 10: ...l on the product and or on the packaging is not to be disposed of with unsorted municipal waste The symbol indicates that this product must not be disposed of with normal household waste It is the responsibility of the owner to dispose of these products and the other electrical and electronic equipment through specific collection facilities appointed by the government or by local authorities 10 WA...

Page 11: ...in general 11 TECHNICAL SUPPORT The Manufacturer is always available for any information required on installation operation or maintenance of the machine The Customer should ask the questions clearly with reference made to this Manual and to the instructions listed Always remember to specify the type of product and the production date on the label under the LCD display mask G Flow display version ...

Page 12: ...i 70 994 70 994 70 994 Precision 0 3 0 3 0 5 Repeatability 0 2 0 2 0 2 Display rotation Complete with 90 steps Input Output BSP G Flange 1 F Flange 1 F Flange 1 F Body material Aluminium Aluminium Aluminium Gear material POM C POM C POM C O Ring material NBR NBR NBR Other materials in contact with the fluid Brass Steel NdFe Brass Steel NdFe Brass Steel NdFe Min max operating temperature C 10 60 10...

Page 13: ...1 Data Tolleranze generali UNI EN 22768 mK SW Massa kg Peso indicativo 02 12 2015 Data Approvato Proprietà Componente Adam Pumps CODE DESCRIPTION QTY DISPLAY PULSE OUT 1 TF066A TF066A METER BODY 1 2 TF065A TF065A FLANGE 1 3 VT040 VT040 SCREW TC M5x16 4 4 OR011 OR011 O RING 37 x 3 NBR 4 5 VT045 VT045 SCREW TBEI M8X25 ZNB 4 6 TF070 TF070 CEMENTED PIN 5X60 2 7 TF040 TF040 MAGNET Ø3x6 4 8 TF071 TF071 ...

Page 14: ...TF065A Cover 1 3 TF064 Inlet flange 2 4 OR011 O Ring 37 x 3 4 5 TF070 cemented pin 5x60 2 6 TF040 Magnet Ø3 4 7 TF071 cemented pin 3x14 2 8 TF018 calibration cap 1 8 1 9 11010100200 O Ring 108 1 10 TF068 oval wheel 4 11 OR033 O Ring 6 532 1 CODE DESCRIPTION QTY 12 TF076 Inlet filter 1 13 TF072 Cover plate 1 14 AC005 Cable gland 1 15 VT036 Nylon Washer 2 20 OR031 O Ring 2 142 1 17 TF077 cemented pi...