39 © Adam Equipment Company 2011
14.
PARAMETER SETTINGS
Pressing the
[Func]
key allows the user to access the parameters for customising the
indicator. The parameters are split into 4 groups-
1. Check weighing parameters,
2. RS-232 parameters
3. Indicator parameters
4. Percent and Animal Weighing Functions
•
When
[Func]
is pressed, display will first show
“FUnC 1”
for Check weighing
parameters.
•
Enter
[2] f
or RS-232 parameters or
[3]
for Indicator parameters or
[4]
for
percent weighing and animal weighing, or press the
[Func]
key to advance
through the groups
“FUnC 1”
,
“FUnC 2”
,
“FUnC 3”
and
“FUnC 4”
. Press
[Tare]
to
enter the desired group of parameters.
•
Press
[Zero]
to return to the group
“FUnC 1”
. If you press
[Zero]
again, the
indicator will exit the User Parameter section and return to normal weighing.
14.1.
CHECK WEIGHING PARAMETERS
•
Shortcut to enter this group is to press and hold the
[Unit]
key for 4 seconds.
The display will go directly to
“FUnC 1”
.
•
Press
[Tare]
to enter the group.
•
Press
[Func]
to scroll through the parameters and press
[Tare]
to enter a
parameter setting.