© Adam Equipment Company 2017
5 of 22
The window for the Weight has arrows to indicate when the scale is at zero
or if the scale is displaying a net weight (if a tare value has been entered). It
also indicates when the scale is stable.
The window for the Unit Price has arrows to show when the Auto Clear
function is active and if the unit price is per 100g or per kilogram.
NOTE: For South Africa and Far East, unit price per 100g or per kg is not
available.
The window for the Total Price displays the price of the items on the scale.
Below this window is a LED to show the status of the battery charging.
2.4 BATTERY CHARGING
•
The scale has an internal rechargeable lead acid battery. This
battery will make the scale operate for 90 hours when fully
charged or less if the backlight is on.
•
When the battery needs charging the arrow above the low battery
symbol under the Weight window will be on and the display
will show “
LO bAt
” for a few seconds and every 2 minutes as a
reminder. The battery should be charged immediately. The scale
will still operate for about 15 minutes after which it will
automatically switch off to protect the battery from getting
damaged.
•
To charge the battery, simply switch the main power ON. The
scale need not be turned on.
•
The battery should be charged for 12 hours for full capacity.
•
Just under the Total Price window is an LED to indicate the
status of battery charging. When the scale is plugged into the
main power, the internal battery will be charged. If the LED is
green the battery is fully charged. If it is red the battery is nearly
discharged and yellow indicates the battery should be charged
longer, preferably overnight.
•
If the battery has not been used properly or it is used for a number
of years it may eventually fail to hold a full charge. If the battery
life becomes unacceptable then contact your distributor or Adam
Equipment.
The above display panel is also available with French, German, Spanish, Dutch
and Italian text or with symbols for Weight, Unit Price and Total Price.