background image

 

© Adam Equipment Company 2017 

 

 

 

 

5  of  22 

The window for the Weight has arrows to indicate when the scale is at zero 
or if the scale is displaying a net weight (if a tare value has been entered). It 
also indicates when the scale is stable. 

 

The  window  for  the  Unit  Price  has  arrows  to  show  when  the  Auto  Clear 
function is active and if the unit price is per 100g or per kilogram. 

 

NOTE: For South Africa and Far East, unit price per 100g or per kg is not 
available. 

 

The window for the Total Price displays the price of the items on the scale.  
Below this window is a LED to show the status of the battery charging. 

 

2.4  BATTERY CHARGING 

 

  The  scale  has  an  internal  rechargeable  lead  acid  battery.  This 

battery  will  make  the  scale  operate  for  90  hours  when  fully 
charged or less if the backlight is on.  

 

  When the battery needs charging the arrow above the low battery 

symbol         under the Weight window will be on and the display 
will  show  “

LO  bAt

”  for  a  few  seconds  and  every  2  minutes  as  a 

reminder.   The battery should be charged immediately. The scale 
will  still  operate  for  about  15  minutes  after  which  it  will 
automatically  switch  off  to  protect  the  battery  from  getting 
damaged. 

 

  To  charge  the  battery,  simply  switch  the  main  power  ON.  The 

scale need not be turned on.  

 

  The battery should be charged for 12 hours for full capacity. 

 

  Just  under  the  Total  Price  window  is  an  LED  to  indicate  the 

status  of  battery  charging.    When  the  scale  is  plugged  into  the 
main  power,  the  internal  battery  will  be  charged.    If  the  LED  is 
green the battery is fully charged.  If it is red the battery is nearly 
discharged  and  yellow  indicates  the  battery  should  be  charged 
longer, preferably overnight. 

 

  If the battery has not been used properly or it is used for a number 

of  years  it  may  eventually  fail  to  hold  a  full  charge.  If  the  battery 
life  becomes  unacceptable then  contact  your  distributor  or  Adam 
Equipment. 

The above display panel is also available with French, German, Spanish, Dutch 

and Italian text or with symbols for Weight, Unit Price and Total Price. 

Summary of Contents for AZextra 30P

Page 1: ...Adam Equipment Company 2017 Adam Equipment AZextra SERIES with EC type Approval P N 6315 Rev D August 2017 Software rev 2 29A above...

Page 2: ...Adam Equipment Company 2017...

Page 3: ...NING VALUE OF A PRODUCT BY WEIGHT 8 3 4 USING A STORED PLU VALUE FOR UNIT PRICE 8 3 5 ENTERING VALUES FOR THE PLU S 100 3 6 AUTO CLEAR KEY 111 3 7 PRICE PER KILOGRAM AND PER 100 GRAM KG 100G KEY 111 3...

Page 4: ...olour coded sealed keypad Large 3 x 6 digits backlit liquid crystal displays LCD Displays for Weight Unit Price and Total Price or Price to Pay Displays on both front and back panels Optional user dis...

Page 5: ...lit LCD displays Housing ABS Plastic with Stainless Steel Pan Overall Dimensions 315 x 355 x 110 mm 315 x 355 x 535 mm Net Weight 4 3 kg 4 7 kg NOTE AZextra P models have the Pillar Display 2 0 INSTAL...

Page 6: ...the cable inside the pillar rod Secure the pillar rod to the socket by using two M4 screws A black plastic cap is provided to seal the socket from the bottom to avoid damaging the cable Level the sca...

Page 7: ...will show LO bAt for a few seconds and every 2 minutes as a reminder The battery should be charged immediately The scale will still operate for about 15 minutes after which it will automatically swit...

Page 8: ...ediately recall the most used PLU values PLU is used to select any of the 99 additional values Tare or key It tares the scale to display zero weight when an empty container is placed on the platform o...

Page 9: ...ts of weight are shown when the platform is empty 3 2 TARING Taring is used to eliminate the weight of a container so that only the net weight is displayed Zero the scale by pressing Zero if necessary...

Page 10: ...m 1 300 0 00 0 00 Key in the unit price 1 300 5 00 6 50 Press the kg 100g key to change the calculation to a price based on the cost per 100g or the cost per kilogram If a different unit price is requ...

Page 11: ...es to PLU2 simply press PLU2 3 To recall one of the other PLU values press PLU The display will show LOAd PoS 00 If a number 00 to 99 is entered immediately then the value saved against the entered PL...

Page 12: ...key Enter the unit price value using the keypad selecting either price kg or price 100g if needed Press and hold down the key PLU for more than 3 seconds till a beep is heard then release the key It...

Page 13: ...rrow on the LCD will be ON Pressing Auto Clear will turn off the function and the indicator will disappear Pressing it will turn the function to on again 3 7 PRICE PER KILOGRAM AND PER 100 GRAM Kg 100...

Page 14: ...ATION The backlight may be enabled or disabled by the user If the backlight is disabled the battery life will be maximised With the backlight in operation the battery life will be less depending on th...

Page 15: ...ng Tare key Z cr If Sets the zero point for all subsequent weighing The display shows zero P cr lf Prints the results to a PC or printer using the RS 232 interface 3 10 2 RS 232 Setup The RS 232 inter...

Page 16: ...9200 Set baud rate LAbEL 1 1 2 or 3 Select label format to print CoUntr Y E nGLiSH EnGLiSH FrEnCH GErMAn or SPAniSH Select Language to be printed StErLi nG EUroPE dOLLAr StErLinG Select currency Euro...

Page 17: ...hange the date and time The display will show the current time format H m S Enter the time using the numeric keys using a 24 hour clock format 3 41PM is 154100 Press the Tare key to accept the time Th...

Page 18: ...error Tried to set an illegal time i e 26 hours Err 2 Date input error Tried to set an illegal date i e 36th day Err 4 Initial Zero is greater than allowed typically 4 of the maximum capacity when po...

Page 19: ...not provided with this hole you need to break the security seals and remove the top cover to gain access to the circuit boards inside See the figure on the security seal below WARNING CALIBRATION OF T...

Page 20: ...other methods B Details of the unit purchased This part of information should always be available for any future correspondence We suggest you to fill in this form as soon as the unit is received and...

Page 21: ...ence faulty installation unauthorised modifications or attempted repair or failure to observe the requirements and recommendations as given in this User Manual This product may include a rechargeable...

Page 22: ...with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user wil...

Page 23: ...Adam Equipment Company 2017 21 of 22...

Page 24: ...49 0 4340 40300 0 Fax 49 0 4340 40300 20 e mail e mail vertrieb aeadam de Adam Equipment S A Pty Ltd 7 Megawatt Road Spartan EXT 22 Kempton Park Johannesburg Republic of South Africa Phone 27 0 11 97...