© Adam Equipment Company 2017
10 of 22
3.5 ENTERING VALUES FOR THE PLU s
To store values for the PLUs into the memory follow the procedure.
Entering values for PLU1 and PLU2 keys
•
Enter the unit price value using the keypad, selecting either price/kg or
price/100g if needed.
•
Press and hold down the key [PLU1] or [PLU2] for more than 3
seconds till a beep is heard, then release the key. The scale displays
“
PLU
” “
1
” ”
SAVEd
” or “
PLU
” “
2
” ”
SAVEd
”, followed by the PLU value
displayed in the Unit Price window.
Entering values for the [PLU+] key
•
Enter the unit price value using the keypad, selecting either price/kg or
price/100g if needed.
•
Press and hold down the key [PLU+] for more than 3 seconds till a
beep is heard, then release the key. It will show “
SAVE
” “
PoS 00
” ” ”.
•
If no number is entered for “
00
” within a few seconds, the PLU entered
will be saved for position 3 which can be recalled in future by using the
[PLU+] key. The display will show “
PLU
” “
3
” ”
SAVEd
” and the scale will
return to weighing.
OR
•
Enter any number (00 up to 99) for saving the unit price in the desired
position. For example, press [1] and [4] for the position 14. It will show
“
PLU
” “
14
” “
SAVEd
” before returning to weighing.
•
To change the earlier saved value against a particular PLU, simply
repeat the process.