Page 46
The Cinema Reference permits access to the “One Time” Setup
functions only through its “Pro Setup”. The Pro Setup is well pro-
tected from accidental access in order to best preserve the Cinema
Reference’s “Out Of The Box” factory default parameters. Since the
Cinema Reference is designed for optimum operation, these pa-
rameters may not need to be adjusted, and as such, under most
circumstances, should be left alone.
The features that are available in Pro Setup are:
Delay Settings - Each channels delay (including Sub) can be set in
0.5 dB steps.
Network Bus - The setting of the ADA Bus™ address.
Final Input - Setting the maximum number of Input Labels that appear on
the Cinema Reference.
System Setup - All bass management features which are input specific.
IRR On/Off - Turning the Cinema Reference’s front panel IR receiver on
and off.
HDR Scale - Setting the High Dynamic Range scale factor for Dolby Digital
(AC-3).
LDR Scale - Setting the Low Dynamic Range scale factor for Dolby Digital
(AC-3).
Re-Equalize - Turning the THX Re-Equalizer on and off for each input.
Timbre Match - Turning the THX Timbre Match on and off for each input.
Decorrelate - Turning the THX Decorrelation on and off for each input.
Auto-Balance - Turning the Auto-Balance on and off for each input.
Repeat Count - Setting the maximum number of consecutive blocks re-
peated before muting for Dolby Digital modes.
Analog Gain - Adjusting the gain control from 0 dB to +9 dB, in 3 dB steps
per input.
PCM Up Scale - Adjusts the higher end of the PCM scale per AC-3 or non-
AC-3 modes.
PCM Dn Scale - Adjusts the lower end of the PCM scale per AC-3 or non-
AC-3 modes.
Input Format - Sets the Dolby Digital decoding input format per input.
Output Format - Sets the active speaker output format per input.
Aux DC Trig 1 - Sets the Auxiliary Trigger #1 to engage with specific inputs.
Aux DC Trig 2 - Sets the Auxiliary Trigger #1 to engage with specific inputs.
To enter the Pro Setup Mode:
1
Turn the MODE knob clockwise until the display reads SETUP
MODE and then press the MODE knob.
2
Turn the MODE knob clockwise to until the display reads
PRO SETUP and press and hold the MODE knob. The
top line of the display will read PRO SETUP and the sec-
ond line of the display will read T-MINUS 10, T-MINUS
9,.....T-MINUS 1. At this time the display will flash and the
top line will return to read PRO SETUP and the second
line will now read the first Pro Setup function, NETWORK
BUS.
3
To exit the Pro Setup Mode, turn any knob other than the
mode and input knobs. Turn the mode knob to access
the above mentioned parameters.
Pro Setup - Enter At Your Own Risk
The Cinema Reference has
additional parameters that can
be set under the Pro Setup
Mode. These parameters are
set in the factory for optimum
performance.
To protect these factory
settings, the ability to access
the Pro Setup mode requires
the turning of the MODE knob
until SETUP MODE appears
followed by pressing and
holding of the MODE knob for
a countdown of ten seconds.
When in the Pro Setup Mode,
you can still access functions
typically limited to the
standard Setup Mode.
There is no time-out function
while in Pro Setup.
To exit the Pro Setup Mode,