Addendum Prestige Chimney Connections :  A1005389 - ADD0070

Addendum - Prestige Chimney Connections   

APPLICABILITY : 
 

664Y6700 - Rev D - Prestige 24-32 Solo/Excellence

 

664Y6200 - Rev F - Prestige 42-50-75-100-120 Solo

 

664Y7100 - Rev A - Prestige Box 200-250-300-350-400-500 LP&RP

RECOMMENDATIONS FOR CHIMNEY CONNECTION

Essential recommendations for safety

• 

 Do  not install the boiler into a common flue piping with any other gas or oil 

appliances. This will cause flue gas spillage or appliance malfunction.

• 

Verify installed combustion air and flue piping are sealed gas tight and meet all 

provided instructions and applicable codes and standards.

• 

Failure to properly support the flue system can cause the flue system to fail, 

resulting in substantial property damage, serious injury, or death.

• 

A byproduct of any gas/oil fired appliance is carbon monoxide. Failure to install 

carbon monoxide detectors with alarms can result in serious injury, or death. Refer 

to applicable local regulations.

Essential recommendations for the correct operation of the appliance
• 

A condensation outlet connected to the sewer must be fitted close to the boiler to 

prevent the condensation products from the flue pipe from running into the boiler.

• 

Install a condensate neutralisation system if required by national and/or local 

regulations and have it cleaned regularly.

• 

Only use flue system components from the same manufacturer to connect this 

appliance and ensure that the pipe and connection diameters all match.

• 

Make sure to secure the flue piping to a solid structure.

• 

Exclusively use provided brackets to support the flue system.

• 

Install the horizontal flue pipes with a slight slope of 5 cm per meter (3°), so that the 

acid condensation water  flows to a condensate recovery container and does not 

damage the heating body.

≤0,5 m

≤2,0 m

≤1,0 m

≤1,0 m

4

1

3

1

≤0,25 m

≤2,0 m

≤0,25 m

4

2

≤0,25 m

≤0,25 m

≤2,0 m

4

2

Slope = 3°

1.  Each elbow and straight element will be secured at the sleeve.
2.  In case the straight element before or after the first elbow is shorter than 25 cm, 

secure the straight element after the elbow using a bracket.

3.  In case a straight (horizontal or sloped) element is longer than 1 m, support the element in 

its center using a clamp, making sure to allow free movement of the pipe.

4.  Secure with a clamp every 2 meters in vertical piping/1 meter in horizontal/sloped 

piping, making sure to distribute the clamps evenly on the length of piping.

• 

If the appliance is provided with a condensate drain assembly, make sure to install 

the complete assembly on the boiler.  If the assembly is incomplete, replace the entire 

assembly.

• 

Make sure that the condensate drain assembly is filled with water before starting 

up the boiler and check regularly the water level. Fill with water as necessary.

• 

It is mandatory to ventilate the boiler room. The high or low air vent opening 

dimensions depend on the boiler power and the boiler room size. Refer to the local 

regulations in force.

• 

If the combustion air inlet is located in an area likely to cause or contain 

contamination, or if products which could contaminate the air cannot be removed, 

the combustion air must be repiped and terminated at another location. 

• 

Pool, laundry, common household, and hobby products often contain fluorine 

or chlorine compounds, which can form strong acids and corrode the internal 

components and flue system.

• 

In the case of parallel flue systems, make sure to maintain sufficient distance 

(at least 40 mm) between the boiler flue piping and combustible materials, and 

between the flue pipe and air inlet pipe if the latter is made of plastic material.

• 

Do not use screws to fasten together any flue pipe elements or any PP air inlet 

elements.

• 

Do not bond piping elements together using glue (e.g. silicone) or foam (e.g. PUR). 

General remark

• 

For safety reasons and to make assembly easier, it is recommended to prefer the 

use of concentric flue pipes when possible.

• 

It is recommended to isolate the flue piping in damp rooms to prevent condensation 

water from forming on the piping and drip.

• 

When cutting the pipes to dimension, make sure to cut squarely and deburr the 

edges to prevent seals from being incorrect or damaged.

• 

To make piping assembly easier, exclusively use a mixture of water and soap (1%) 

on the extremity of the pipe to be fit in.

• 

When fitting metal flue pipes, make sure to always fit the pipe into the sleeve to 

the end stop.

• 

When fitting plastic flue pipes, make sure to allow material expansion by leaving 

about 10 mm between the pipe end and the sleeve end stop.

• 

Make sure to install the piping without any strain.

• 

Make sure to install an inspection opening in the flue system.

• 

When connecting the flue pipes, make sure not to exceed the maximum length 

recommended for the product, otherwise the system power might decrease.

• 

ACV-approved components will be used for the chimney connection. Failure to do 

so will make any warranty claim void.

• 

For C63 connection type (not allowed in Belgium), make sure to use the correct 

piping material according to the resistance to temperature, pressure, chemical 

composition of flue, condensation and soot. A code (as explained in EN 1443), 

marked on the pipe, allows to determine if the material complies with the flue 

system requirements.

EN

Summary of Contents for Prestige Box 200 LP

Page 1: ...A1004849 664Y7100 A EN FR NL ES IT DE PL RU 200 250 300 350 400 500 LP RP Prestige Box INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS for the Installer and the User...

Page 2: ...mity i a w Royal Decree BE APPLICABILITY 664Y7100 Rev A Prestige Box 200 250 300 350 400 450 500 LP RP NOx Class 6 Classe 6 Klass 6 Klasse 6 Weighted Pond r Gewogen Gewichtet Prestige Box 200 300 400...

Page 3: ...Addendum Nox Values A1007428 ADD0170...

Page 4: ...plete assembly on the boiler If the assembly is incomplete replace the entire assembly Make sure that the condensate drain assembly is filled with water before starting up the boiler and check regular...

Page 5: ...ige 42 50 75 C93 PP Flex 80 Set C93 80 125 537D6287 Flexible PP PP 80 25 m 537D6275 Connection sheath Alu for 80 125 537D6266 Connector Flex Flex PP 80 537D6448 Prestige 24 32 Prestige 42 50 75 C13 C3...

Page 6: ...7D6219 Flue 150 90 537D6220 Air 100 45 537D6221 Air 100 90 537D6222 Element for measurement and recovery of conden sates flue 150 537D6223 Weather Slate Steep 25 45 537D6209 Bracket 150 mm 537D6210 We...

Page 7: ...tremplid eauavantded marrer lachaudi reetv rifierr guli rementleniveaud eau Leremplird eausin cessaire La ventilation de la chaufferie est obligatoire Les dimensions de l ouverture haute ou basse d pe...

Page 8: ...Flex 80 Set C93 80 125 537D6287 Tube flexible PPS 80 25 m 537D6275 Fourreau de raccord ement pour concen trique 537D6266 Adaptateur Flex Flex PP 80 537D6448 Prestige 24 32 Prestige 42 50 75 C13 C33 PP...

Page 9: ...um es 150 45 537D6219 Fum es 150 90 537D6220 Air 100 45 537D6221 Air 100 90 537D6222 Tube de mesure avec r cup rateur de condensats fum es 150 537D6223 Solin r glable 25 45 537D6209 Fixation 150 mm 53...

Page 10: ...het waterniveau Vul met water indien nodig Deventilatievandestookruimteisverplicht Deafmetingenvandebovenverluchting of onderverluchting zijn afhankelijk van het vermogen van de ketel en het volume va...

Page 11: ...se pan plat dak 350 mm 537D6362 Adapter 60 100 2 x 80 met meetopeningen 537D6415 Prestige 24 32 Prestige 42 50 75 C93 PP Flex 80 Toebehoren Set C93 80 125 537D6287 25 m flexibele buis PPS 80 537D6275...

Page 12: ...6214 500 mm 537D6215 1000 mm 537D6216 Lengte lucht PVC 100 500 mm 537D6217 Lengte regelbaar rook 150 537D6218 Rook 150 45 537D6219 Rook 150 90 537D6220 Lucht 100 45 537D6221 Lucht 100 90 537D6222 Meet...

Page 13: ...Addendum Prestige Chimney Connections A1005389 ADD0070...

Page 14: ...Addendum Prestige Chimney Connections A1005389 ADD0070...

Page 15: ...f Corrosion and Scaling in Heating Systems 11 INSTALLATION 12 Safety instructions for the installation 12 Package Contents 12 Moving the Prestige Box 12 Tools required for the installation 12 Opening...

Page 16: ...nspection and transport faults may occur Please immediately notify your approved installer of any faults en 3 Prestige Box A1004849 664Y7100 A EN FR NL ES IT DE PL RU If you smell gas Immediately isol...

Page 17: ...on the Prestige Solo boilers and their technical characteristics installed in the Prestige Box refer to the Prestige Solo Installation Operation and Maintenance Instructions List of Prestige box mode...

Page 18: ...ion draining circuit closed 7 Plate to plate Heat exchanger 8 Main gas pipe 9 Transport slot s 10 Safety devices INAIL group optional 11 Condensate neutralisation system 12 Seal equipped openings left...

Page 19: ...erall height Base and chimney incl mm 2479 5 2479 5 2479 5 2479 5 2479 5 2479 5 Overall Width base incl mm 800 800 800 800 800 800 Chimney connection mm 100 100 100 100 100 100 Min of flue pipe mm 100...

Page 20: ...4100 626 1717 1 1004 2 2 2 2 50 mm 1 1 2 800 en 7 Prestige Box A1004849 664Y7100 A EN FR NL ES IT DE PL RU TECHNICAL CHARACTERISTICS...

Page 21: ...80 80 Max C 110 110 110 110 110 110 Min C 30 30 30 30 30 30 Mass flow rate of flue gases Nominal kg h 166 1 193 0 166 1 193 0 166 1 193 0 at min output kg h 21 0 21 0 21 0 21 0 21 0 21 0 Max gas flow...

Page 22: ...ermostat Safety Pressostat 1 2 3 X2 PE 1 X2 L1 2 X2 N1 3 X2 S 4 X2 O 5 X2 L2 6 X2 N2 7 X2 N 9 X2 NS 10 X2 NS 11 X2 L1 12 X2 PE 13 1 C 230V 24V 1 COM NC NC COM NC COM Boilers Q1 3N 4N 1 2 Q2 3N 4N 1 2...

Page 23: ...ting Conditions Maximum temperature primary 87 C Water Quality See Recommendations for the Prevention of Corrosion and Scaling in Heating Systems on following page HYDRAULIC CHARACTERISTICS Prestige B...

Page 24: ...circuit The larger the water volume in the system the larger the addition Hydraulic components without an oxygen barrier PE pipes and connections admit oxygen into the system Prevention Principles 1...

Page 25: ...l the Prestige box on a base made of non combustible materials Make sure that all air vents are unobstructed at all times A condensation outlet connected to the sewer must be fitted to the Prestige Bo...

Page 26: ...GAS CONNECTION ELECTRICAL CONNECTION Essential recommendations for safety Install a manual gas shut off valve outside the Prestige box on the gas supply tube to the Prestige box Check that the gas typ...

Page 27: ...Control the tightness of the hydraulic circuit connections TOOLS REQUIRED FOR STARTING UP FILLING THE HEATING CIRCUIT General Remark Depending on the box model selected connections will be located on...

Page 28: ...rical power supply on Gas supply open Hydraulic circuit full of water Procedure 1 Check that there is no gas leak 2 Push in the ON OFF master switch of the boiler s 3 Refer to the Prestige Solo Instal...

Page 29: ...by a qualified engineer and the defective parts may only be replaced by genuine factory parts Refer to the boiler installation Operation and Maintenance manual for the correct procedures Control the t...

Page 30: ...er to the Installation Oper ation and Maintenance manual of the boiler for more infor mation X 5 Check the flue gas exhaust correct fastening correct instal lation no leaks or clogging X 6 Check the c...

Page 31: ...Prestige Box A1004849 664Y7100 A en 18 EN FR NL ES IT DE PL RU DECLARATION OF CONFORMITY...

Page 32: ...PRESTIGE 42 50 75 100 120 Solo A1004849 664Y7100 A EN FR NL ES IT DE PL RU en 19...

Page 33: ...PRESTIGE 42 50 75 100 120 Solo A1004849 664Y7100 A en 20 EN FR NL ES IT DE PL RU...

Page 34: ...PRESTIGE 42 50 75 100 120 Solo A1004849 664Y7100 A EN FR NL ES IT DE PL RU en 21...

Page 35: ...PRESTIGE 42 50 75 100 120 Solo A1004849 664Y7100 A en 22 EN FR NL ES IT DE PL RU...

Page 36: ...PRESTIGE 42 50 75 100 120 Solo A1004849 664Y7100 A EN FR NL ES IT DE PL RU en 23...

Page 37: ...PRESTIGE 42 50 75 100 120 Solo A1004849 664Y7100 A en 24 EN FR NL ES IT DE PL RU...

Reviews: