Addendum Prestige Chimney Connections : A1005389 - ADD0070
Boiler M
odels
Conne
xion t
ype
Material /
Ø (mm)
Components *
Terminals
Pipes
Extensions
Bends
Measurement and con-
densate recovery
Accessories
Adapters
Pr
estige 42-50-75-
100-120
C13
C33
PP - Galva
Ø 100/150
• Roof Terminal
(537D6300)
• Wall terminal kit
(537D6301)
Lengths :
• 250 mm (
537D6302)
• 500 mm (537D6303)
• 1000 mm (537D6304)
• 2000 mm (537D6517)
Sliding extension, straight
(+ 50 to 130 mm)
(537D6305)
• 43° - 45° (537D6306)
• 87° - 90° (537D6307)
• Measuring Tube
( 537D6308)
• Measuring T-piece with
inspection (537D6310)
• Weather Slate Steep
25°-45° (537D6209)
• Bracket Ø 150 mm
(537D6210)
• Weather Slate, Flat roof
(Ø 430 mm) (537D6208)
Concentric to parallel
adapter Ø 100/150 mm - 2 x
Ø 100 mm (537D6207)
Pr
estige 42-50-75-100-120
B23P
C53
SST
Ø 150
• Roof Terminal , flue
Ø 150
(537D6211)
• Wall terminal kit , flue,
Ø 150
(537D6212)
• Wall terminal kit, air,
Ø 100
(537D6213)
Lengths, flue, Ø 150 :
• 250 mm (
537D6214)
• 500 mm (537D6215)
• 1000 mm (537D6216)
Length, air, PVC Ø 100 :
• 500 mm (
537D6217)
Sliding extension, flue,
Ø 150
(537D6218)
• Flue, Ø 150, 45°
(537D6219)
• Flue, Ø 150, 90°
(537D6220)
• Air, Ø 100, 45°
(537D6221)
• Air, Ø 100, 90°
(537D6222)
Element for measurement
and recovery of conden-
sates, flue,
Ø 150
(537D6223)
• Weather Slate Steep
25°-45° (537D6209)
• Bracket Ø 150 mm
(537D6210)
• Weather Slate, Flat roof
(Ø 430 mm) (537D6208)
• Expander Ø 100 -
Ø 150 mm mandatory
(537D6293)
• Concentric to parallel
adapter Ø 100/150
mm - 2 x Ø 100 mm
(537D6207)
• Adapter Ø 80 - Ø 100
mm, air (537D6172)
Pr
estige 42-50-75-100-120
C13
C33
SST - SST
Ø 100/150
• Roof Terminal,
(537D6197)
• Wall terminal
(537D6198)
Lengths :
• 250 mm (
537D6199)
• 500 mm (537D6200)
• 1000 mm (537D6201)
Sliding extension (280 to
395 mm)
(537D6202)
• 43° - 45° (537D6203)
• 87° - 90° (537D6204)
Element for measurement
and recovery of conden-
sates, flue, (537D6226)
• Weather Slate Steep
25°-45° (537D6209)
• Bracket Ø 150 mm
(537D6210)
• Weather Slate, Flat roof
(Ø 430 mm) (537D6208)
Concentric to parallel
adapter Ø 100/150 mm - 2 x
Ø 100 mm (537D6207)
Pr
estige B
ox
The chimney connection should be made using the chimney tubes and seals provided with the Prestige Box.
Only parallel flue pipe connection types are possible, NO concentric.
* Designations and references (between brackets) are provided as information only. Please refer to the latest ACV brochure for more information and the correct references.
EN
Summary of Contents for Prestige Box 200 LP
Page 3: ...Addendum Nox Values A1007428 ADD0170...
Page 13: ...Addendum Prestige Chimney Connections A1005389 ADD0070...
Page 14: ...Addendum Prestige Chimney Connections A1005389 ADD0070...
Page 31: ...Prestige Box A1004849 664Y7100 A en 18 EN FR NL ES IT DE PL RU DECLARATION OF CONFORMITY...
Page 32: ...PRESTIGE 42 50 75 100 120 Solo A1004849 664Y7100 A EN FR NL ES IT DE PL RU en 19...
Page 33: ...PRESTIGE 42 50 75 100 120 Solo A1004849 664Y7100 A en 20 EN FR NL ES IT DE PL RU...
Page 34: ...PRESTIGE 42 50 75 100 120 Solo A1004849 664Y7100 A EN FR NL ES IT DE PL RU en 21...
Page 35: ...PRESTIGE 42 50 75 100 120 Solo A1004849 664Y7100 A en 22 EN FR NL ES IT DE PL RU...
Page 36: ...PRESTIGE 42 50 75 100 120 Solo A1004849 664Y7100 A EN FR NL ES IT DE PL RU en 23...
Page 37: ...PRESTIGE 42 50 75 100 120 Solo A1004849 664Y7100 A en 24 EN FR NL ES IT DE PL RU...