Installer's Handbook (Evo) - 660Y3000 • A
EN
PRESET CONFIGURATION 16
Pump Configuration 16
Con-
fig. No
Flex 4
ERR
Flex 6
P4
Flex 3
P3
Flex 2
DHW
Flex 1
CH
Flex 5
FL
16
Error/Flame
CH2
CH1/CH2
CH1
CH1/CH2/
DHW
Flame
ACVMax Touch settings using the Installer menu
(Installer code needed, see
Main
Screen
Sub-
screen
item
Sub-item
Required selection
Model
HeatMaster (Pre-Set)
Pump Settings
Preset Pump Config
Config 16
Heating Operation
Enabled ( )
Demand
Thermostat and
setpoint
CH2 Circuit
Disabled
DHW Operation
Enabled (
)
Demand
Sensor
CH1
CH
High temperature heating circuit, possibly with optional outdoor
temperature sensor and room thermostat.
Warm water
Cold water
Installing a three way valve in the heating supply will allow to control the temperature
of the water supply to the heating system. Please contact your ACV representative for
more information.
Electrical board terminals
Terminal /pins
to connect
AC
V M
ax
1
2
3
4
5
6
1
2
3
4
5
6
W
W
W
W
W
W
4
5
6
1
2
3
1
2
3
4
6
X
15
1
2
3
4
5
6
7
8
9
10
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
X
11
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
17
16
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
11
12
13
14
W
R
Or
Bk
Bk
Bk
V
Bk
4
2
1
3
2
1
1
2
3
1
2
3
4
5
6
8
9
10
11
12
1
2
3
4
5
13
6
14
7
X2
1
2
3
4
5
6
7
8
9
10
W
R
Y
R
Y
BK
BK
W
6
7
8
9
10
1
2
3
4
5
X3
1
2
3
4
5
6
7
8
9
10
11
12
V
W
R
Bk
7
8
9
10
11
1
2
3
4
5
12
6
X1
R
Bk
Bk
Y
Y
Bk
Bk
R
R
W
W
V
Or
Bk
Bk
R
Bk
W
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
W
W
W
W
W
W
W
V
1
2
3
4
5
1
2
3
4
5
8
Bk
2
3
1
15
12
13
14
X
12
X9
P
14
1
2
3
4
1
2
3
4
5
6
B
V
B
W
P
13
B
Or
1
2
3
Bk
B
Y/Gr
V
Br
B
Br
Br
Y/Gr
B
B
4
5
6
7
8
8
7
6
5
4
1
2
3
5
F0
0
X
10
0
N
L
N
L
V
ON / OFF
3
230 V
~ 50Hz
1
N
L
N
L
N
L
2
6
B
Y/Gr
Br
B
Y/Gr
Br
Br
B
Bk
B
Y/Gr
Y/Gr
Y/Gr
Y/Gr
Y/Gr
Y/Gr
Y/Gr
Y/Gr
W
B
Br
Br
B
Br
Y/Gr
B
X
101
4
X
10
1
2
X20
1624
2
1
1
NTC 5
9
2
1
1
NTC 2
10
2
1
1
NTC 1
11
Br
B
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
1
X103
X103
Harness
code: A10021
14
25
X
18
V
W
B
W
B
B
9
10
11
12
13
14
15
16
16
15
14
13
12
11
10
9
X
10
0
7
Y/Gr
Y/Gr
B
W
B
W
B
V
B
Br
Y/Gr
B
Br
B
Br
Y/Gr
P4
P3
FL
26
1
1
3
3
6
6
4
4
7
7
8
8
9
9
5
5
2
2
5AT Fuse
5AT Fuse
5AT Fuse
PUMP PWM
Br
Br
B
B
B
V
Y/Gr
C
M
1
2
3
1
2
3
27
AC
V M
ax
1
2
3
4
5
6
1
2
3
4
5
6
7
8
9
Or
Bk
Bk
Bk
V
Bk
4
2
1
3
2
1
8
9
10
11
12
1
2
3
4
5
13
6
1
2
3
4
5
6
7
8
9
10
W
R
Y
R
Y
BK
BK
W
6
7
8
9
10
1
2
3
4
5
X3
1
2
3
4
5
6
7
8
9
10
11
12
V
W
R
Bk
7
8
9
10
11
1
2
3
4
5
12
6
X1
R
Bk
Bk
Y
Y
Bk
Bk
R
R
W
W
V
Or
Bk
Bk
W
V
1
2
3
4
5
1
2
3
4
5
8
Bk
12
13
14
X
12
X9
P
14
1
2
3
4
1
2
3
4
5
6
B
V
B
W
P
13
B
Or
1
2
3
Bk
B
Y/Gr
V
Br
B
Br
Br
Y/Gr
B
B
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
1
2
3
5
F0
0
X
10
0
N
L
N
L
ON / OFF
3
230 V
~ 50Hz
1
N
L
N
L
N
L
2
6
B
Y/Gr
Br
B
Y/Gr
Br
Br
B
Bk
B
Y/Gr
Y/Gr
Y/Gr
Y/Gr
Y/Gr
Y/Gr
Y/Gr
Y/Gr
W
B
Y/Gr
Br
Br
B
B
Y/Gr
B
Or
Br
B
Br
Y/Gr
B
X
101
4
X
10
1
2
X20
2
1
1
NTC 5
9
2
1
1
NTC 2
10
2
1
1
NTC 1
11
Br
B
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
1
X103
X103
Harness
code: A10021
14
L
N
230 V
V
W
B
W
B
B
9
10
11
12
13
14
15
16
16
15
14
13
12
11
10
9
X
10
0
7
Y/Gr
Y/Gr
B
W
B
W
B
V
B
Br
Y/Gr
B
Br
B
Br
Y/Gr
P4
P3
FL
26
1
1
3
3
6
6
4
4
7
7
8
8
9
9
5
5
2
2
5AT Fuse
5AT Fuse
5AT Fuse
PUMP PWM
Br
Br
B
B
B
V
Y/Gr
C
M
1
2
3
1
2
3
27
..... Flex 6
(9/ - 10/L - 11/N)
..... Flex 5
(12/L - 13/N)
..... Flex 3
(14/ - 15/L - 16/N)
..... Flex 4
(1/L - 2/N)
..... Flex 2
(3/ - 4/N - 5/L)
--
Flame sensor
--
Error (Alarm)
-
ACV Max
1
2
3
4
5
6
1 2 3 4 5 6
W
W
W
W
W
W
4
5
6
1
2
3
1
2
3
4
6
X15
1 2 3 4 5 6 7 8 9 10
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
X11
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
17
16
3
4
1
2
X16
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10 11 12 13 14
W
R
Or
Bk
Bk
V
Bk
4
2 1
3 2 1
1 2 3
1 2 3 4 5 6
8
9
10 11 12
1
2
3
4
5
13
6
14
7
X2
1 2 3 4 5 6 7 8 9 10
W
R
Y
R
Y
BK
BK
W
6
7
8
9
10
1
2
3
4
5
X3
1 2 3 4 5 6 7 8 9 10 11 12
V
W
R
Bk
7
8
9
10 11
1
2
3
4
5
12
6
X1
R
Bk
Y
Y
Bk
Bk
R
R
W
W
V
Or
Bk
Bk
R
Bk
W
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
W
W
W
W
W
W
W
V
1
2
3
4
5
1 2 3 4 5
8
Bk
2
3
1
15
12
13
14
X12
X9
P14
1
2
3
4
1
2
3
4
5
6
B
V
B
W
P13
B
Or
1
2
3
Bk
B
Y/Gr
W
Br
B
Br
B
F00
W
230 V ~ 50Hz
1
N
L
N
L
N
L
2
B
Y/Gr
Br
B
Y/Gr
Br
Y/Gr
Y/Gr
Y/Gr
Y/Gr
X101
19
18
21
20
22
25
X10
1
2
X20
16
26
2 1
1
NTC 5
9
2 1
1
NTC 2
10
2 1
1
NTC 1
11
1
2
3
1
2
1
2
3
4
1
2
3
4
5
6
X7
X4
X6
X5
Bus A
Bus - Ground
Bus B
0-10 Volt - Ground
0-10 Volt - Input
Cascade sensor - Ground
Cascade sensor - Input
NTC 3
NTC 4
1
2
23
24
27
X18
W
B
W
B
11 12 13 14 15 16
16
15
14
13
12
11
X100
7
Y/Gr
B
W
B
W
B
V
B
Br
Y/Gr
B
Br
P3
FL
28
230 V
5A
T F
use
5A
T F
use
5A
T F
use
............DHW sensor (NTC3)
............Optional outdoor temp. sensor (NTC4)
............Optional room thermostat 1
For outdoor sensor characteristics,
refer to
temperature sensors" on page 36
SYSTEM DIAGRAMS AND SET-UP
Summary of Contents for ACVMax Touch