GENERAL WEATHER STATION FUNCTIONS

After the initial and general set-up, the following data will be displayed in different sections 
on the main unit display.

MOON PHASE:

The moon phase indicator, found under the date display, shows the current phase of the 
moon based on the yearly calendar.

CALENDAR FUNCTION: 

The calendar display, found under the time display shows the 

current month and date with day indicator.

FORECAST ICONS:

 The main unit predicts weather conditions for the next 12 – 24 hours 

based on the change in temperature and atmospheric pressure. The coverage area is up to 
25 miles. Weather forecasts based on atmospheric pressure changes are about 70-75% 
accurate. As weather conditions cannot be 100% correctly forecasted, we cannot be 
responsible for any loss caused by an incorrect forecast. 

More than 20 icons will represent the 24 hr. weather forecast. Some common icons include:

TREND INDICATORS:

 Trend indicators for outdoor temperature and humidity and wind 

speed show the trend tendency based on the past and current weather conditions.

BAROMETRIC BAR GRAPH AND PRESSURE HISTORY:

 The main unit shows BARO-

METRIC pressure in two forms, numerically and as a pressure history graph. The graph 
indicates the pressure changes (range from +0.24inHg to -0.24inHg/ -8hPa mb to +8 hPa 
mb) of the current and past 1,2,3,6 and 12 hours. 

WIND FUNCTIONS:

Digital Compass:

 The digital compass indicates

the direction from which the wind is coming from,
marked by the arrow indicator, with 16 possible
directions. The wind direction is shown here
coming out of the 

WEST

.

Wind Speed:

 The wind speed values are located in

the center of the digital compass. The wind speed
is transmitted from the wind sensor and is
updated approximately every 18 seconds. The wind
speed shown here is 4 (mph).

Wind Peak:

 The wind Peak displays the highest recorded

wind speed over he past 1 hour.

SPEED

WEATHER AND TIME ALARMS

ALARM SETTING MODE: 

The alarm setting mode allows the user to change several alarm 

settings, which is done by accessing one mode after the other, simply by pressing the 
“ALARM”” button. The individual alarm can be turned on and off by using the 
“ON/OFF/RECORDS” button. When an alarm goes off, an audible tone will sound for one 
minute.

Press and hold the “ALARM” button for 3 seconds to enter the alarm setting mode. The 
time display and “AL” for alarm will be blinking. This indicates the user is now in the 
alarm-setting mode. In alarm setting mode, to activate or deactivate any alarm, press the 
“ON/OFF     ” button.

For non-time alarms, the blinking “HH.H” means the high alarm value is to be set.
For non-time alarms, the blinking “LL.L” means the low alarm value is to be set.

While in the alarm mode, use “MIN” (-) or “MAX” (+) buttons to change any of the values. 
Press and hold for rapid scroll through of any values. Press the “EXIT” button to exit any of 
the above alarm modes. Press the “ALARM” button to stop the alarm for one day, or press 
the “SNOOZE” button to turn the alarm time off for five-minute increments.

This weather station also comes equipped with a audible storm alarm. When activated, the 
storm alarm will sound if there is a sudden or extreme drop in barometric pressure or if 
there is a constant progressive drop in barometric pressure. NOTE: If no button is pressed 
for 30 seconds, the alarm setting mode returns to the normal display mode.

Pressing the “ALARM” button during the alarm-setting mode scrolls through the following 
settings:
1. Time alarm setting (hours, minutes)
2. Indoor temperature alarm (high, low)
3. Indoor humidity alarm (high, low)
4. Outdoor temperature alarm (high, low, at the current channel)
5. Outdoor humidity alarm (high, low)
6. Wind chill alarm (low)
7. Heat index alarm (high)
8. Dew point alarm (high, low)
9. Wind speed alarm
10. Storm alarm

MINIMUM & MAXIMUM RECORD MODE

The “MIN/MAX” buttons provide the user with information about the minimum and 
maximum values of today’s weather data. It also acts as an access mode for the daily and 
long-term records, with the time and date of their recordings. 

TO ACCESS THE MIN OR MAX VALUES (TODAY’S HIGH’S AND LOW’S):

Press the “MIN” or “MAX” button to display the corresponding highs or lows of the day. 

10

11

SUNNY

RAINY / SNOW

CLOUDY

PARTLY CLOUDY

Summary of Contents for 00595

Page 1: ......

Page 2: ...r which receives data from the atomic clock in Fort Collins Colorado and then sends the received data back to the main unit display The data is sent by a 433MHz radio controlled wireless transmission Transmission can be received up to 100 feet away in an unobstructed open area WIRELESS WIND SPEED SENSOR The wind sensor measures wind speed and wind direction and transmits this information to the ma...

Page 3: ...ERY INSTALLATION For the first installation insert the batteries into the two WIRELESS SENSORS FIRST and then into the main unit Thermo Hygrometer Sensor See illustration next page Rotate and pull the top casing from the bottom cone by turning the unit upside down and rotating counter clock wise until casing pulls apart Insert 2 fresh AA batteries batteries not included Replace the battery compart...

Page 4: ... a signal search press and hold the CHANNEL button for 3 seconds RADIO CONTROLLED ATOMIC CLOCK The Radio Controlled Atomic Clock RCC signal from Fort Collins CO is relayed through the wireless thermo hygrometer sensor If the RCC signal has successfully been received will be displayed If the RCC signal has not been received only the icon will be displayed The RCC signal is best received at night an...

Page 5: ... activated The ALARM icon will be displayed and blinking GENERAL SET UP The general setting mode allows the user to change several product default settings which is done by simply accessing one setting after the other by pressing the SET UP button In normal mode press and hold the SET UP button for 3 seconds to enter the manual set up mode The icon to set will be blinking If no key is pressed for ...

Page 6: ...ngs which is done by accessing one mode after the other simply by pressing the ALARM button The individual alarm can be turned on and off by using the ON OFF RECORDS button When an alarm goes off an audible tone will sound for one minute Press and hold the ALARM button for 3 seconds to enter the alarm setting mode The time display and AL for alarm will be blinking This indicates the user is now in...

Page 7: ...ues These values show the highest or lowest values ever recorded on the weather station To obtain the historical details for these records press the RECORDS button and the record along with time and date will be blinking Press the RECORDS button again to scroll through each of the unit s minimum and maximum record values CLEARING LONG TERM RECORDS To clear long term records press either the MIN or...

Page 8: ... Daily History 14 15 ...

Page 9: ...DEL 00594W Do not return product to retail store For Technical Assistance and product return information please contact Customer Care at 877 221 1252 HOURS Monday through Friday from 8 00 a m to 5 00 pm CST Records 2009 EST 19 0 Wind Peak ...

Page 10: ......

Reviews: