Installation and Commissioning Guide
Split Tri-Capacity
43
Installation and Commissioning Guide 500-700 Tri-Capacity Split Ducted
Doc. No.0525-098
Ver. 2 210330
17.02. Service Menu
(PASSWORD PROTECTED)
(P
ASS
W
ORD PR
O
TECTED
)
(P
ASS
W
ORD PR
O
TECTED
)
(P
ASS
W
ORD PR
O
TECTED
)
Ga1.
Enter Language Change
Gfc17
(OD)
-
Gfc18
(ID)
.
Alarms Disable
Rtn Air Sensor Y/N
Ga.
Change Language
Gb.
Information
Gb1.
Software Information
Gb2.
Hardware Information
Gd2.
Setpoint logging / Reset
Gd3.
Supply Fan logging / Reset
Main Menu
G. Service
Gc.
Board Switch
Gd1.
Indoor Fan Hr Run / Filter hr
Comp. Hr Run (Crt 1,2 and 3)
Ge1.
BMS Configuration
Address
Protocol
Speed (baud rate)
Ge2.
Enable BMS to Turn the
Unit On/Off
On loss of Comms On/Off
Gfa1.
Indoor Filter
Filter Fault Rly Y/N
Indoor Fan
Compressor
Ge3.
Enable DIN4 to Turn the
Unit On/Off
Gd.
Working Log
Gfa.
Working Hour se
t
Gf.
Service Setting
Gfc.
Thermoregulation
Ge.
Communicate Config
Gfc1.
Room Temp. Setpoint
Dead Band
Cooling Prop band
Heating Prop band
Integral time
Gfc2.
Room Temp use ID sensor
After Hours (SW & Temp./SW Only)
Probe weight value
Room Temperature
Wall Control Temp.
Control Value
Gfc6.
Room Setpoint limit
Minimum / Maximum by User
User Setpoint Lock/Unlock
User mode sel. Lock/Unlock
Mode Lock Timer Setting
Gfc4.
Supply Fan Speed
Min/ Med/ Max
Supply Fan Temp.
Min / Max
Gfc5.
Supply fan Gen. 3/Continuous : Y/N
Cycle on de-ice Setting : Y/N
Number of Fan Speed Setting
Supply Fan Run On Setting
Heat Start Delay Setting
Gfc13.
Type of Fans Fitted
Supply / Outdoor
Outdoor Init Speed (%) & OF1/OF23
Econ. cycle fitted: Y/N
Econ. cycle type: Mod:On/Off
Gfc7.
Enable Night Mode by Sched.
Start/Stop Finish Time
Max Cond fan spd & cct 2 max spd
Gfc12.
Unit Configuration
Series, Model & Variations
Gfc11.
Unit Mode Configuration
Supply Fan Control Setting
Select Wall Control
Gfa2.
Reset ID Fan / Filter
/ Comp.
Unit Address
Switch to Unit
Gfb.
Probe Adjustment
Gfb1.
Room Temp. Calibration
Multi Input Calibration
Ga2.
Disable Language Mask at
Startup: Yes/No
Gb4.
Fan Board Information
Gfc19.
Damper Scaling
Command Start / End
Output Start / End
Gfc31.
CO
2
Control Start / End
Alarm Output: enable/Disable
Sensor Fault
Gfc8.
Sensor present:
Multi Input 1/2: Y/N
Supply Air Temp
CO
2
Sensor
Economy Enable
Night Mode Enable
0-10V Stage Cont
0-10V In Fan Spd
View Only Input
Phase Fail Relay
Gfc14.
Default Initialisation
Erase User settings and
install global default value Y/N
Gfc15.
Room Temp / Humidity
Gfc16.
Outside Temp / Humidity
Sensor fitted/Use this temp sensor
Gfc32.
Compressors
1st Stage Start / Stop
2nd Stage Start / Stop
3rd Stage Start / Stop