actiLib Autoloader 1U
– User and Service Guide
Page 84 of 97
D0
ROM error
ROM checksum incorrect
Retry of Firmware
upgrade, if not successful
contact technical support
D1
RAM error
Power on Self Test ( POST ) has failed,
Retry operation; after
several occurrences
contact technical support
D2
NVRAM error
R/W operation to NVRAM has failed
Retry operation; after
several occurrences
contact technical support
D5
Display Error
Communication to display failed
Retry operation; after
several occurrences
contact technical support
D7
Fatal system error
Retry operation; after
several occurrences
contact technical support
D8
Data base error
Retry operation; after
several occurrences
contact technical support
D9
No SCSIIC detected
Retry operation; after
several occurrences
contact technical support
DA
In Wellness Test the barcode reader has read
different barcode data for the same cartridge
label
Check barcode on scratch
cartridge and run
‘LoaderHealth Check’
again. If the error recurs,
contact technical support
DB
External cooling fan error (fan motion has
stopped).
The sub code indicates which drive sled fan is
affected
Check if the indicated fan
is operational and not
obstructed.
If the error persists,
contact technical support
F0
Drive Over temperature Condition
Sub code 00: drive sled #1
Sub code 01: drive sled #2
Check ambient
temperature conditions
and check all fans, after
several occurrences
contact technical support
F1
Drive Communication Error,
Loader controller has lost communication to
drive
Retry operation; if not
successful contact
technical support