CONFIGURATION
Jumpers
E
E26
E27
E5
E26 and E27 Polarization of REVERSE, ODOMETER inputs when open circuit: By default, jumpers
are not present
Signal
REVERSE
ODOMETER
Low level
E26 = P
E27 = P
High level
E26 = NP
E27 = NP
Low level => signal activation by connection to b
High level => signal activation by connection to battery ground
E5
NP
No 120 ohm terminator on Interface CAN
P*
120 ohm terminator on Interface CAN