1-1

OUTLINE AND DIMENSIONS

Indoor Unit: Ceiling Concealed Fan Coil Unit F Series

LEFT PIPING

All dimensions are in mm

KE

1

3

D

K

321

183

48

31

KC
KB

140

KA

32

20

552

129

20

11

143

87

71

247

186

31

RIGHT PIPING

All dimensions are in mm

KE

KD

KC

KB

KA

31

321

183

48

31

140

32

552

11

186

87

71

31

247

20

20

129

143

Dimension

Model

KA

KB

KC

KD

KE

06/09FWD

619

477

437

440

501

12/15FWD

870

726

687

690

751

18FWD

1060

916

877

880

941

24FWD

1390

1246

1207

1210

1271

30FWD

1600

1456

1417

1420

1481

Original Instruction

English

IM-CCFWD-0117(1)L-ACSON.indb   1

IM-CCFWD-0117(1)L-ACSON.indb   1

5/31/2017   10:14:55 AM

5/31/2017   10:14:55 AM

Summary of Contents for 06FWD

Page 1: ...MANUAL CEILING CONCEALED CHILLED WATER FAN COIL UNIT F SERIES IM CCFWD 0117 1 L ACSON Part No R08019046054A IM CCFWD 0117 1 L ACSON indb i IM CCFWD 0117 1 L ACSON indb i 5 31 2017 10 14 55 AM 5 31 201...

Page 2: ...IM CCFWD 0117 1 L ACSON indb ii IM CCFWD 0117 1 L ACSON indb ii 5 31 2017 10 14 55 AM 5 31 2017 10 14 55 AM...

Page 3: ...dimensions are in mm KE KD KC KB KA 31 321 183 48 31 140 32 552 11 186 87 71 31 247 20 20 129 143 Dimension Model KA KB KC KD KE 06 09FWD 619 477 437 440 501 12 15FWD 870 726 687 690 751 18FWD 1060 9...

Page 4: ...e Ensure that the unit s panel is closed after service or installation Unsecured panels will cause the unit to operate noisily Sharp edges and coil surfaces are potential locations which may cause inj...

Page 5: ...movable Field supply Washer for hanger bracket attached Tighten Detail A CAUTION Do not install the unit at altitude over 2000m for both indoor and outdoor Ceiling Concealed Drain Piping Work DRAIN PI...

Page 6: ...ypes of piping and connection must be insulated with closed cell polyurethane to avoid condensation Do not use contaminated or damaged pipe and fitting for installation Some main fitting components ar...

Page 7: ...type of installation and size of conductors The appropriate voltage range should be checked with label data on the unit A main switch or other means for disconnection having a contact separation in al...

Page 8: ...pressure 16 bar Air temperature as below Cooling Mode Temperature Ts C F Th C F Minimum indoor temperature 19 0 66 2 14 0 57 2 Maximum indoor temperature 32 0 89 6 23 0 73 4 Ts Dry bulb temperature T...

Page 9: ...2nd air filter with 1st air filter hook Push the air filter to the end of air filter rail Put back the side air filter cover Figure 2 Install air filter from bottom Figure 4 Insert the 1st air filter...

Page 10: ...f the air conditioner unit is noted immediately switch off the power supply to the unit Check the following fault conditions and causes for some simple troubleshooting tips Fault Causes Action 1 The a...

Page 11: ...IM CCFWD 0117 1 L ACSON indb 9 IM CCFWD 0117 1 L ACSON indb 9 5 31 2017 10 14 56 AM 5 31 2017 10 14 56 AM...

Page 12: ...without prior notification All images are for illustration purposes only Lot 60334 Persiaran Bukit Rahman Putra 3 Taman Perindustrian Bukit Rahman Putra 47000 Sungai Buloh Selangor Darul Ehsan Malaysi...

Reviews: