background image

1-2

INSTALLATION MANUAL

This manual provides the procedures of installation to ensure a safe and good standard of operation for the air conditioner unit.
Special adjustment may be necessary to suit local requirement.
Before using your air conditioner, please read this instruction manual carefully and keep it for future reference.
This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial 
use by lay persons.
This appliance is not intended for use by persons, including children, with reduced physical, sensory or mental capabilities, or 
lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a 
person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.

SAFETY PRECAUTIONS

 WARNING 

•  Installation and maintenance should be performed by quali

fi

 ed 

persons who are familiar with local code and regulation, and 
experienced with this type of appliance.

• All 

fi

 eld wiring must be installed in accordance with the 

national wiring regulation.

•  Ensure that the rated voltage of the unit corresponds to that of 

the name plate before commencing wiring work according to 
the wiring diagram.

•  The unit must be GROUNDED to prevent possible hazard due 

to insulation failure.

•  All electrical wiring must not touch the refrigerant piping, or 

any moving parts of the fan motors.

• Con

fi

 rm that the unit has been switched OFF before installing 

or servicing the unit.

•  Disconnect from the main power supply before servicing the 

air conditioner unit.

•  DO NOT pull out the power cord when the power is ON. This 

may cause serious electrical shocks which may result in 

fi

 re 

hazards.

•  Keep the indoor and outdoor units, power cable and 

transmission wiring, at least 1m from TVs and radios, to 
prevent distorted pictures and static. {Depending on the type 
and source of the electrical waves, static may be heard even 
when more than 1m away}.

 

CAUTION

Please take note of the following important points when 

installing.

•  Ensure that the drainage piping is connected properly.

If the drainage piping is not connected properly, it may 

cause water leakage which will dampen the furniture.

•  Ensure that the unit’s panel is closed after service or 

installation.

Unsecured panels will cause the unit to operate noisily.

•  Sharp edges and coil surfaces are potential locations which 

may cause injury hazards. Avoid from being in contact with 

these places.

•  Before turning off the power supply set the remote controller’s 

ON/OFF switch to the “OFF” position to prevent the nuisance 

tripping of the unit. 

If this is not done, the unit’s fans will start 

turning automatically when power resumes, posing a hazard to 

service personnel or the user.

•  Do not install the units at or near doorway.

•  Do not install the units at area like hot spring or oil re

fi

 nery 

plant where sulphide gas exists.

•  Do not operate any heating apparatus too close to the air 

conditioner unit or use in room where mineral oil, oil vapour or 

oil steam exist, this may cause plastic part to melt or deform as a 

result of excessive heat or chemical reaction.

•  When the unit is used in kitchen, keep 

fl

 our away from 

going into suction of the unit.

•  This unit is not suitable for factory used where cutting oil 

mist or iron powder exist or voltage 

fl

 uctuates greatly.

•  Ensure the color of wires of the outdoor unit and the 

terminal markings are same to the indoors respectively.

•  IMPORTANT : DO NOT INSTALL OR USE THE AIR 

CONDITIONER UNIT IN A LAUNDRY ROOM.

•  Don’t use joined and twisted wires for incoming power 

supply.

•  The equipment is not intended for use in a potentially 

explosive atmosphere.

NOTICE

Disposal requirement

Your air conditioning product is marked with this symbol. This means that electrical and electronic products shall not be mixed 

with unsorted household waste.

Do not try to dismantle the system yourself: the dismantling of the air conditioning system, treatment of the refrigerant, of oil and of 

other parts must be done by a qualifi ed installer in accordance with relevant local and national legislation.

Air conditioners must be treated at a specialized treatment facility for re-use, recycling and recovery. By ensuring this product 

is disposed of correctly, you will help to prevent potential negative consequences for the environment and human health. Please 

contact the installer or local authority for more information.

Batteries must be removed from the remote controller and disposed of separately in accordance with relevant local and national 

legislation.

IM-CCFWD-0117(1)L-ACSON.indb   2

IM-CCFWD-0117(1)L-ACSON.indb   2

5/31/2017   10:14:55 AM

5/31/2017   10:14:55 AM

Summary of Contents for 06FWD

Page 1: ...MANUAL CEILING CONCEALED CHILLED WATER FAN COIL UNIT F SERIES IM CCFWD 0117 1 L ACSON Part No R08019046054A IM CCFWD 0117 1 L ACSON indb i IM CCFWD 0117 1 L ACSON indb i 5 31 2017 10 14 55 AM 5 31 201...

Page 2: ...IM CCFWD 0117 1 L ACSON indb ii IM CCFWD 0117 1 L ACSON indb ii 5 31 2017 10 14 55 AM 5 31 2017 10 14 55 AM...

Page 3: ...dimensions are in mm KE KD KC KB KA 31 321 183 48 31 140 32 552 11 186 87 71 31 247 20 20 129 143 Dimension Model KA KB KC KD KE 06 09FWD 619 477 437 440 501 12 15FWD 870 726 687 690 751 18FWD 1060 9...

Page 4: ...e Ensure that the unit s panel is closed after service or installation Unsecured panels will cause the unit to operate noisily Sharp edges and coil surfaces are potential locations which may cause inj...

Page 5: ...movable Field supply Washer for hanger bracket attached Tighten Detail A CAUTION Do not install the unit at altitude over 2000m for both indoor and outdoor Ceiling Concealed Drain Piping Work DRAIN PI...

Page 6: ...ypes of piping and connection must be insulated with closed cell polyurethane to avoid condensation Do not use contaminated or damaged pipe and fitting for installation Some main fitting components ar...

Page 7: ...type of installation and size of conductors The appropriate voltage range should be checked with label data on the unit A main switch or other means for disconnection having a contact separation in al...

Page 8: ...pressure 16 bar Air temperature as below Cooling Mode Temperature Ts C F Th C F Minimum indoor temperature 19 0 66 2 14 0 57 2 Maximum indoor temperature 32 0 89 6 23 0 73 4 Ts Dry bulb temperature T...

Page 9: ...2nd air filter with 1st air filter hook Push the air filter to the end of air filter rail Put back the side air filter cover Figure 2 Install air filter from bottom Figure 4 Insert the 1st air filter...

Page 10: ...f the air conditioner unit is noted immediately switch off the power supply to the unit Check the following fault conditions and causes for some simple troubleshooting tips Fault Causes Action 1 The a...

Page 11: ...IM CCFWD 0117 1 L ACSON indb 9 IM CCFWD 0117 1 L ACSON indb 9 5 31 2017 10 14 56 AM 5 31 2017 10 14 56 AM...

Page 12: ...without prior notification All images are for illustration purposes only Lot 60334 Persiaran Bukit Rahman Putra 3 Taman Perindustrian Bukit Rahman Putra 47000 Sungai Buloh Selangor Darul Ehsan Malaysi...

Reviews: