IMPORTANT NOTICE

CORK TAPE FULLY INSTALLED

INSULATION THROUGH OUT CHILLED WATER PIPING

WATER PIPING CONNECTION

•  The indoor unit is equipped with water outlet and inlet connection. There is an air-vent that is 

fi

 tted along 

with the connection for air purging.

•  3 way valve is required for cycling off or bypass the chilled water.
•  Black steel pipe, closed cell polyurethane pipe and copper tube are recommended in the 

fi

 eld installation. 

All types of piping and connection must be insulated with closed cell polyurethane to avoid condensation.

•  Do not use contaminated or damaged pipe and 

fi

 tting for installation.

• Some main 

fi

 tting components are needed in the system to enhance the capacity and ease of service, such as 

gate valve, balancing valve, 2 way or 3 way valve, strainer and etc.

Chiller

Gate Valve

Gate Valve

FCU

Three Way Valve

Gate Valve

Gate Valve

FCU

Two Way Valve

g

n

il

l

o

r

t

n

o

C

 

d

a

B

g

n

il

l

o

r

t

n

o

C

 

d

o

o

G

Gate Valve

Gate Valve

FCU

Worst Controlling

IM-CCFWD-0117(1)L-ACSON.indb   4

IM-CCFWD-0117(1)L-ACSON.indb   4

5/31/2017   10:14:56 AM

5/31/2017   10:14:56 AM

Summary of Contents for 06FWD

Page 1: ...MANUAL CEILING CONCEALED CHILLED WATER FAN COIL UNIT F SERIES IM CCFWD 0117 1 L ACSON Part No R08019046054A IM CCFWD 0117 1 L ACSON indb i IM CCFWD 0117 1 L ACSON indb i 5 31 2017 10 14 55 AM 5 31 201...

Page 2: ...IM CCFWD 0117 1 L ACSON indb ii IM CCFWD 0117 1 L ACSON indb ii 5 31 2017 10 14 55 AM 5 31 2017 10 14 55 AM...

Page 3: ...dimensions are in mm KE KD KC KB KA 31 321 183 48 31 140 32 552 11 186 87 71 31 247 20 20 129 143 Dimension Model KA KB KC KD KE 06 09FWD 619 477 437 440 501 12 15FWD 870 726 687 690 751 18FWD 1060 9...

Page 4: ...e Ensure that the unit s panel is closed after service or installation Unsecured panels will cause the unit to operate noisily Sharp edges and coil surfaces are potential locations which may cause inj...

Page 5: ...movable Field supply Washer for hanger bracket attached Tighten Detail A CAUTION Do not install the unit at altitude over 2000m for both indoor and outdoor Ceiling Concealed Drain Piping Work DRAIN PI...

Page 6: ...ypes of piping and connection must be insulated with closed cell polyurethane to avoid condensation Do not use contaminated or damaged pipe and fitting for installation Some main fitting components ar...

Page 7: ...type of installation and size of conductors The appropriate voltage range should be checked with label data on the unit A main switch or other means for disconnection having a contact separation in al...

Page 8: ...pressure 16 bar Air temperature as below Cooling Mode Temperature Ts C F Th C F Minimum indoor temperature 19 0 66 2 14 0 57 2 Maximum indoor temperature 32 0 89 6 23 0 73 4 Ts Dry bulb temperature T...

Page 9: ...2nd air filter with 1st air filter hook Push the air filter to the end of air filter rail Put back the side air filter cover Figure 2 Install air filter from bottom Figure 4 Insert the 1st air filter...

Page 10: ...f the air conditioner unit is noted immediately switch off the power supply to the unit Check the following fault conditions and causes for some simple troubleshooting tips Fault Causes Action 1 The a...

Page 11: ...IM CCFWD 0117 1 L ACSON indb 9 IM CCFWD 0117 1 L ACSON indb 9 5 31 2017 10 14 56 AM 5 31 2017 10 14 56 AM...

Page 12: ...without prior notification All images are for illustration purposes only Lot 60334 Persiaran Bukit Rahman Putra 3 Taman Perindustrian Bukit Rahman Putra 47000 Sungai Buloh Selangor Darul Ehsan Malaysi...

Reviews: