SERVICE AND MAINTENANCE

Service Parts

Maintenance Procedures

Period

Indoor Air Filter

1. Remove any dust adhering to the 

fi

 lter by using a 

vacuum cleaner or wash in lukewarm water (below 
40°C) with a neutral cleaning detergent.

2. Rinse the 

fi

 lter well and dry before placing it back onto 

the unit.

3. Do not use gasoline, volatile substances or chemicals to 

clean the 

fi

 lter.

At least once
every 2 weeks.

More frequently if
necessary.

Indoor Unit

1. Clean any dirt or dust on the grille or panel by wiping 

it with a soft cloth soaked in lukewarm water (below 
40°C) and a neutral detergent solution.

2. Do not use gasoline, volatile substances or chemicals to 

clean the indoor unit.

At least once
every 2 weeks.

More frequently if
necessary.

 

CAUTION

Avoid direct contact of any coil treatment cleaners on plastic part. This may cause plastic part to 
deform as a result of chemical reaction.

TROUBLESHOOTING

For any enquiries on spare parts, please contact your authorized dealer. If any malfunction of the air
conditioner unit is noted, immediately switch off the power supply to the unit. Check the following fault
conditions and causes for some simple troubleshooting tips.

Fault

Causes / Action

1. The air conditioner unit does not operate.

 

– Power failure, or the fuse need to be replaced.

 

– The power plug is disconnected.

 

– It is possible that your delay timer has been set 

incorrectly.

2. The air 

fl

 ow is too low.

 

– The air 

fi

 lter is dirty.

 

– The doors or windows are open.

 

– The air suction and discharge are clogged.

 

– The regulated temperature is not high enough.

3. Discharge air 

fl

 ow has bad odor.

 

– Odors may be caused by cigarettes, smoke 

particles, perfume etc. which might have adhered 
onto the coil.

4. Condensation on the front air grille of the indoor 

unit.

 

– This is caused by air humidity after an extended 

long period of operation.

 

– The set temperature is too low, increase the 

temperature setting and operate the unit at high 
fan speed.

5. Water 

fl

 owing out from the air conditioner unit.

 

– Switch off unit and call local dealer / serviceman.

If the fault persists, please call your local dealer / serviceman.

IM-CCFWD-0117(1)L-ACSON.indb   8

IM-CCFWD-0117(1)L-ACSON.indb   8

5/31/2017   10:14:56 AM

5/31/2017   10:14:56 AM

Summary of Contents for 06FWD

Page 1: ...MANUAL CEILING CONCEALED CHILLED WATER FAN COIL UNIT F SERIES IM CCFWD 0117 1 L ACSON Part No R08019046054A IM CCFWD 0117 1 L ACSON indb i IM CCFWD 0117 1 L ACSON indb i 5 31 2017 10 14 55 AM 5 31 201...

Page 2: ...IM CCFWD 0117 1 L ACSON indb ii IM CCFWD 0117 1 L ACSON indb ii 5 31 2017 10 14 55 AM 5 31 2017 10 14 55 AM...

Page 3: ...dimensions are in mm KE KD KC KB KA 31 321 183 48 31 140 32 552 11 186 87 71 31 247 20 20 129 143 Dimension Model KA KB KC KD KE 06 09FWD 619 477 437 440 501 12 15FWD 870 726 687 690 751 18FWD 1060 9...

Page 4: ...e Ensure that the unit s panel is closed after service or installation Unsecured panels will cause the unit to operate noisily Sharp edges and coil surfaces are potential locations which may cause inj...

Page 5: ...movable Field supply Washer for hanger bracket attached Tighten Detail A CAUTION Do not install the unit at altitude over 2000m for both indoor and outdoor Ceiling Concealed Drain Piping Work DRAIN PI...

Page 6: ...ypes of piping and connection must be insulated with closed cell polyurethane to avoid condensation Do not use contaminated or damaged pipe and fitting for installation Some main fitting components ar...

Page 7: ...type of installation and size of conductors The appropriate voltage range should be checked with label data on the unit A main switch or other means for disconnection having a contact separation in al...

Page 8: ...pressure 16 bar Air temperature as below Cooling Mode Temperature Ts C F Th C F Minimum indoor temperature 19 0 66 2 14 0 57 2 Maximum indoor temperature 32 0 89 6 23 0 73 4 Ts Dry bulb temperature T...

Page 9: ...2nd air filter with 1st air filter hook Push the air filter to the end of air filter rail Put back the side air filter cover Figure 2 Install air filter from bottom Figure 4 Insert the 1st air filter...

Page 10: ...f the air conditioner unit is noted immediately switch off the power supply to the unit Check the following fault conditions and causes for some simple troubleshooting tips Fault Causes Action 1 The a...

Page 11: ...IM CCFWD 0117 1 L ACSON indb 9 IM CCFWD 0117 1 L ACSON indb 9 5 31 2017 10 14 56 AM 5 31 2017 10 14 56 AM...

Page 12: ...without prior notification All images are for illustration purposes only Lot 60334 Persiaran Bukit Rahman Putra 3 Taman Perindustrian Bukit Rahman Putra 47000 Sungai Buloh Selangor Darul Ehsan Malaysi...

Reviews: