TC 120
682.98767.00 • 10/04/2018
44
8-2 Technical Specifications
Table 1: TC 120 Specifications
Dimensions
Shipping
Pump
H
W
D
weight
hp
kW
gpm
lpm
psig
kPa
in.
cm
in. cm in. cm
lbs.
Kg
¾
0.56
30
113.6
25
172.4
28¾”
73.0
14
35.6
28
71.1
210
96
1
0.75
35
132.5
30
206.9
2
1.50
50
189.3
30
206.9
3
2.24
60
227.1
35
241.3
5
3.73
90
340.7
50
344.8
240
109
7½
5.60
120
454.2
50
344.8
Table 2: Additional Specifications
Model
Full-load amps at 460 volts
Pressure drop flow and loss
hp
kW
9 kW htr 12 kW htr 18 kW htr 24 kW htr flow gpm
flow lpm
loss psi
loss kPa
0.75 hp
0.56 kW
12.7 amps 16.5 amps 24.0 amps 31.6 amps 30.0 gpm
113.6 lpm
0.0 psi
0.0 kPa
1.00 hp
0.75 kW
13.1 amps 16.9 amps 24.4 amps 32.0 amps 35.0 gpm
132.5 lpm
1.0 psi
6.9 kPa
2.00 hp
1.50 kW
14.7 amps 18.5 amps 26.0 amps 33.6 amps 50.0 gpm
189.3 lpm
1.5 psi
10.3 kPa
3.00 hp
2.24 kW
16.1 amps 19.9 amps 27.4 amps 35.0 amps 60.0 gpm
227.1 lpm
2.0 psi
13.8 kPa
5.00 hp
3.73 kW
18.9 amps 22.7 amps 30.2 amps 37.8 amps 75.0 gpm
283.9 lpm
2.5 psi
17.2 kPa
7.50 hp
5.60 kW
22.3 amps 26.1 amps 33.6 amps 41.2 amps 90.0 gpm
340.7 lpm
5.0 psi
34.4 kPa
To calculate full load amps at 230 volts, multiply by
2.0
.
8-3 Drawings and Diagrams