2-5 Available Options
Temperature control unit systems are available with options to tailor the unit to your
requirements. Some are factory installed; some can be retro-fitted in the field. Consult
ACS Group sales for more information. Available TCU options include:
Digital flow meter with:
Up to 30 gpm (114 lpm) flow indicator
- or -
30 to 60 gpm (114 to 227 lpm) flow indicator
- or -
Greater than 60 gpm (> 227 lpm) flow indicator
1/16 DIN PID Temperature controller with:
4-20 mA current control output
Retransmission and remote set point; 4-20 mA, 2-10 V
RS-232 or RS-485 communications (Modbus, SPI,
Ethernet)
Remote sensor; 10 ft. (3 m)
Remote controller enclosure
Heaters available in 12 kW, 18 kW, and 24 kW; 18 kW and
24 kW heaters available on 5 hp and 7½ hp (3.73 kW, 5.60
kW) direct-injection models only
3.7 sq. ft. closed-loop heat exchanger
Auto system water purge (mold purge)
Y-strainer
Hammer arrestor (water hammer shock stop)
Remote start/stop control
Rubber feet; available in lieu of casters
Non-ferrous brass construction
Slow-close cooling solenoid valves available in
1
/
2
” x
9
/
16
” (C
V
= 3.5) and
3
/
4
” x
3
/
4
” (C
V
= 5.5)
Modulating valves available in
1
/
2
” (C
V
= 0.4, 1.3, 2.2, or
4.4),
3
/
4
” (C
V
= 5.5 or 7.5), 1” (C
V
= 11), and 1
1
/
4
” (C
V
= 16)
Two-zone stack rack with casters; common wiring and piping
available
300ºF (149ºC) operation; includes silicon carbide seal