![ACS Marathon MV1012 Operation And Installation Manual Download Page 46](http://html1.mh-extra.com/html/acs/marathon-mv1012/marathon-mv1012_operation-and-installation-manual_3046898046.webp)
Page 46
ACS GROUP Marathon Series Beside-the-Press Granulators
Problem
Possible cause
Solution
Belts slip or squeal.
Belts are too loose.
Tighten per maintenance
instructions.
Pulleys are not properly
aligned.
Loosen and align as needed.
Motor does not start.
Fuses are blown.
Replace fuses with the size
and type being removed.
A limit switch is open.
Check all limit switches at the
cutting chamber cover
plate/hopper, auger trough,
and any hopper clean-out
door. Ensure proper
actuation and replace as
needed.
Verify that the correct push
buttons are being depressed
and that the main disconnect
switch is in the
ON
position.
Granulate builds up in the
transition or tubing.
Fan is too small.
Replace with larger unit or
larger fan wheel.
Transition or tubing is
clogged from overloading the
machine.
Reduce amount of feedstock
put into the machine per unit
of time.
Return air vents are covered
or too small.
Ensure the vents are open.
Fan wheel is loose on shaft.
Tighten set screws as
required.
Summary of Contents for Marathon MV1012
Page 3: ...ACS GROUP Marathon Series Beside the Press Granulators Page 3 Notes ...
Page 16: ...Page 16 ACS GROUP Marathon Series Beside the Press Granulators Notes ...
Page 26: ...Page 26 ACS GROUP Marathon Series Beside the Press Granulators Notes ...
Page 42: ...Page 42 ACS GROUP Marathon Series Beside the Press Granulators Notes ...
Page 47: ...ACS GROUP Marathon Series Beside the Press Granulators Page 47 Service Notes ...
Page 48: ...Page 48 ACS GROUP Marathon Series Beside the Press Granulators Service Notes ...