If the
Run Point
value is correct,
Turn Off Engine
is
automatically displayed after the engine rpm exceeds the value
on the third line.
5. Turn the key to the
off
position. (Press
Cancel
to return to the
Monitor
menu.)
Continue to the next section.
21.3 Input odometer reading
After the tach or speed threshold has been set,
Odometer
is
displayed.
1. Set the odometer value (press
–
or
+
to change a digit, and
press
Select
to move to the next digit).
2. After entering the last digit value, press
Select
, then press
ACCEPT
. (Press
Correct
to reset the odometer value.)
Continue to the next section.
21.4 Performing an ITE monitor transaction
After the odometer value has been accepted,
Monitor
Complete Connect to PC
is displayed.
1. Disconnect the HS from the HS cable.
2. Using the USB cable (79-008958), connect the HS to the UCS
or DS and perform an ITE monitor transaction.
NOTE: Refer to the ITE application manual for the monitor
transaction procedure.
–