BusWorks
®
900EN-S005 Ethernet Switch User’s Manual Ethernet I/O
___________________________________________________________________
_______________________________________________________________________________________
Acromag, Inc. Tel:248-624-1541 Fax:248-624-9234 Email:
http://www.acromag.com
9
+
+
34
32
31
33
15-36VDC
TB3
POWER
GND
DC+
DC+
DC-
EARTH
GROUND
PUSH
TO
RESET
INPUT POWER
IS ISOLATED
REDUNDANT POWER (15-36V DC)
S1
S2
DC-
33
DC+
32
RS
10
9
6
5
2
1
3
9
8
5
4
1
0
DA
11
7
2 3
ST
8
4
0
10
7
6
2 3
ST
9
8
5
4
1
0
DA
11
7
2 3
ST
100M
LK /
P1
X3
X4
TB3
CH. I/O STATUS
ACT
ACT
CH. I/O STATUS
RUN
X5
X5
X4
X1
GND
34
DC+
31
8
4
0
RUN
DA
LINK
11
7
ST
LINK
10
6
DA
RS
LINK
9
11
5
1
RS
LINK
10
6
RUN
COL
ACT
X5
X3
X2
X1
X2
PGM
PORT
PUSH
TO
RESET
ACT
ACT
ETHERNET
Acromag
CH. I/O STATUS
CH. I/O STATUS
POWER
RS
RUN
RUN
ETHERNET
SWITCH
Acromag
ETHERNET
ETHERNET
Acromag
Acromag
ETHERNET
Acromag
HOST PC
Acromag 9xxEN-4012
Ethernet Modules.
The ethernet port of these
modules are not automatic
MDI/MDI-X crossover, but
the use of an auto-crossing
switch eliminates the need
to make a distinction between
straight-through and crossover
cables.
(Straight-Through or Crossover Cable)
CAT-5 UTP CABLE
UP TO 100 METERS
(Straight-Through or Crossover Cable)
Order Acromag Cable Model 5035-355
CAT-5 UTP CABLE
UP TO 100 METERS
ETHERNET
SWITCH
DIP SW S1/S2
CFG OPTIONS
CAT-5 UTP CABLE
UP TO 100 METERS
(Straight-Through or Crossover Cable)
(Straight-Through or Crossover Cable)
CAT-5 UTP CABLE
UP TO 100 METERS
CAT-5 UTP CABLE
UP TO 100 METERS
The ethernet port of the PC is
generally not automatic MDI/MDI-X
crossover and is wired MDI.
Because the Acromag ethernet switch
900EN-S005 is automatic MDI/MDI-X
crossover, use of a direct (straight-through)
or crossover cable is permissible.
IMPORTANT: IF THE HOST PC CONNECTS DIRECTLY TO THE MODULE,
YOU MUST USE A CROSS-CONNECT CABLE (MDI-X), AS BOTH THE PC
AND THE 9XXEN MODULE ETHERNET PORTS ARE WIRED MDI.
ETHERNET SWITCHES AND HUBS ARE WIRED MDI-X.
THE ACROMAG ETHERNET SWITCH IS AUTOMATIC MDI/MDI-X AND
ELIMINATES THE NEED FOR MAKING A DISTINCTION BETWEEN
THE USE OF STRAIGHT-THROUGH (MDI) AND CROSSOVER (MDI-X)
CABLE CONNECTIONS.
Acromag 900EN-S005
5-Port Ethernet Switch
or equivalent.
The ethernet ports of this
switch are automatic MDI/MDI-X
crossing and do not require
crossover cables.
USE OF AN ETHERNET SWITCH TO NETWORK
A HOST PC TO MORE THAN ONE MODULE
Acromag offers a straight-through patch cable (Model 5035-355), or a
crossover cable (Model 5035-360) for use with Series 9xxEN modules.
You can use this switch to build a network of Acromag Ethernet modules,
similar to that shown below. This drawing shows how to network-connect
this switch to a host PC and four Acromag Series 9xxEN Ethernet I/O
modules.
9
Connect 15-36V DC to the power terminals labeled DC+ & DC-.
Optionally connect redundant (backup) power to the second DC+
terminal. Observe proper polarity. For supply connections, use No. 14
AWG wires rated for at least 75
°
C.
CAUTION:
Do not exceed 36VDC
peak.
9
Connection to program port P1 is not required to achieve basic
operation.
Connection to this port is only required if you wish to make
use of more advanced programmable features of this device, such as
port-based VLAN support, broadcast storm protection, rate limiting, and
priority control. An optional accessory cable (Model 5035-365) and
software are required to interface with this port. This software is
included on the CDROM that contains this manual and shipped with your
unit, or it may be optionally downloaded from our web site at
www.acromag.com. Refer to the Technical Reference section at the
back of this manual for more information regarding advanced features
and optional program port connections.
CONNECTIONS
Network
Power
Voltage
Current
15VDC
164mA
18VDC
134mA
24VDC
101mA
36VDC
72mA
Optional Program Port
(Adjacent To DIP
Switch S2)
This connection requires an
optional programming cable,
Acromag Model 5035-365.